49
6-14. ERROR RATE CHECK
6-14-1. CD Error Rate Check
Checking Procedure :
1. Load a check disc (MD) TDYS-1.
2. Move the multi-stick and display “CPLAY1MODE” (C34).
3. Press the PUSH ENTER button twice and display “CPLAY1
MID”.
4. The display changes to “C1 =
AD =
”.
5. Check that the C1 error rate is below 20.
6. Press the CLEAR button while REC IT is lit, stop playback,
press the MD
Z
button while REC IT is off, and remove the
test disc.
6-14-2. MO Error Rate Check
Checking Procedure :
1. Load a continuously recorded test disc (MDW-74/GA-1).
(Refer to “6-5. Using the Continuously Recorded Disc”.)
2. Move the multi-stick and display “CPLAY1MODE” (C34).
3. Press the PUSH ENTER button and display “CPLAY1MID”.
4. The display changes to “C1 =
AD =
”.
5. If the C1 error rate is below 20, check that ADER is 00.
6. Press the CLEAR buttonwhile REC IT is lit, stop playback,
press the MD
Z
button while REC IT is off, and remove the
test disc.
6-15. FOCUS BIAS CHECK
Change the focus bias and check the focus tolerance amount.
Checking Procedure :
1. Load a continuously recorded test disc (MDW-74/GA-1).
(Refer to “6-5. Using the Continuously Recorded Disc”.)
2. Move the multi-stick and display “CPLAY1 MODE”(C34).
3. Press the PUSH ENTER button twice and display “CPLAY1
MID”.
4. Press the CLEAR button while REC IT is lit when “C1 =
AD =
” is displayed.
5. Move the multi-stick and display “FBIAS CHECK”(C16).
6. Press the PUSH ENTER button and display “
/
c =
”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [c =] indicate the
focus bias value.
Check that the C1 error is below 20 and ADER is below 2.
7. Press the PUSH ENTER button and display “
/
b =
”.
Check that the C1 error is below 100 and ADER is below 2.
8. Press the PUSH ENTER button and display “
/
a =
”.
Check that the C1 error is below 100 and ADER is below 2
9. Press the CLEAR button while REC IT is lit, next press the
MD
Z
button while REC IT is off and remove the continuously
recorded disc.
Note 1 : If the C1 error and ADER are above other than the speci-
fied value at points a (step 8. in the above) or b (step 7. in
the above), the focus bias adjustment may not have been
carried out properly. Adjust perform the beginning again.
6-16. AUTO GAIN CONTROL OUTPUT LEVEL
ADJUSTMENT
Be sure to perform this adjustment when the Optical pick-up is re-
placed.
If the adjustment results becomes “Adjust NG!”, the Optical pick-
up may be faulty or the servo system circuits may be abnormal.
6-16-1. CD Auto Gain Control Output Level Adjustment
Adjusting Procedure :
1. Insert the check disc (MD) TDYS-1.
2. Move the multi-stick to display “AG Set (CD)” (C11).
3. When the PUSH ENTER button is pressed, the adjustment will
be performed automatically.
“Complete!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (CD)” (C11).
4. Press the MD
Z
button while REC IT is off and remove the
disc.
6-16-2. MO Auto Gain Control Output Level Adjustment
Adjusting Procedure :
1. Insert the reference disc (MDW-74/GA-1) for recording.
2. Move the multi-stick to display “AG Set (MO)” (C10).
3. When the PUSH ENTER button is pressed, the adjustment will
be performed automatically.
“Complete!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (MO)” (C10).
4. Press the MD
Z
button while REC IT is off and remove the
disc.
Содержание HCD-ZX50MD
Страница 9: ...9 BD CD BOARD To repair the BD CD board remove the bottom plate Bottom view ...
Страница 39: ...39 Adjustment Location BD CD BOARD SIDE B TP VC TP RF TP TEO TP FEO TP GND TP AGCCON IC102 TP XPCK ...
Страница 66: ...HCD ZX50MD 66 66 7 11 SCHEMATIC DIAGRAM MAIN 1 4 SECTION See page 65 for Printed WIring Board ...
Страница 67: ...HCD ZX50MD 67 67 7 12 SCHEMATIC DIAGRAM MAIN 2 4 SECTION See page 65 for Printed WIring Board ...
Страница 75: ...HCD ZX50MD 75 75 7 20 SCHEMATIC DIAGRAM AMP US AEP UK G AED CIS model SECTION ...
Страница 77: ...HCD ZX50MD 77 77 7 22 SCHEMATIC DIAGRAM AMP E MX AR HK MY SP KR AUS model SECTION ...
Страница 81: ...HCD ZX50MD 81 81 7 26 SCHEMATIC DIAGRAM SWITCH SECTION ...
Страница 83: ...HCD ZX50MD 83 83 7 28 SCHEMATIC DIAGRAM CD MECHANISM SECTION 09 Page 68 Page 68 R S ...
Страница 87: ...HCD ZX50MD 87 87 7 34 SCHEMATIC DIAGRAM POWER SUPPLY US AEP UK G AED CIS model SECTION T6 3AL T6 3AL 125V ...
Страница 89: ...HCD ZX50MD 89 89 7 34 SCHEMATIC DIAGRAM POWER SUPPLY E MX AR HK MY SP KR AUS model SECTION AUS 250V 250V 250V ...
Страница 116: ...116 MEMO ...