![Sony HCD-V4800 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/sony/hcd-v4800/hcd-v4800_service-manual_420889018.webp)
– 18 –
1. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head demagnetizer close to the erase
head.)
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual. (As a general rule, playback circuit adjust-
ment should be completed before performing recording circuit
adjustment.)
6. The adjustments should be performed for both L-CH and R-ch.
7. Switches and controls should be set as follows unless otherwise
specified.
8. Set to test mode. (Press key switch same time
GROOVE ENTER/NEXT and DISC 4 buttons.)
To exit from the test mode, press the POWER button.
SECTION 4
MECHANICAL ADJUSTMENTS
SECTION 5
ELECTRICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab:
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
•
Torque Measurement
Mode
Torque Meter
Meter Reading
Forward
CQ-102C
36 to 61g•cm
(0.50 – 0.84 oz•inch)
Forward
CQ-102C
2 to 6g•cm
Back Tension
(0.026 – 0.082 oz•inch)
Reverse
CQ-102RC
36 to 61g•cm
(0.50 – 0.84 oz•inch)
Reverse
CQ-102RC
2 to 6g•cm
Back Tension
(0.026 – 0.082 oz•inch)
FF, REW
CQ-201B
61 to 143g•cm
(0.85 – 1.98 oz•inch)
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 100 g (3.53 oz)
Reverse
CQ-403R
more than 100 g (3.53 oz)
DECK SECTION
0 dB=0.775 V
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
P-4-L300
315 Hz, 0 dB
Level Adjustment
Record/Playback Head Azimuth Adjustment
set
MAIN board
CN207
pin
3
(L-CH)
pin
1
(R-CH)
MAIN board
CN207
pin
2
(GND)
+
–
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
•
Tape Tension Measurement
• Test Tape
DECK A
DECK B
Note:
Perform this adjustments for both decks.
Procedure:
1. Mode: Playback (FWD)
Screw
position
L-CH
peak
within
1 dB
output
level
L-CH
peak
R-CH
peak
within
1 dB
Screw
position
R-CH
peak
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw so
that outputs match within 1 dB of peak.