24
HCD-TB20
4.
After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location: Record/Playback/Erase Head
Tape Speed Check
Note: Set the test mode using the following method and begin tape
speed adjustment.
Procedure:
With the power turned on, press the
x
button, ENTER button,
and CD 3 button simultaneously.
(The message “MD” is displayed while in the test mode.)
To exit the test mode, press the
"/1
button.
1.
Insert the WS-48B into deck.
2.
Press the
Y
button of deck.
3.
Check the reading of frequency counter becomes 3000 ± 90 Hz.
Sample Value of Wow and flutter
W.RMS (JIS) less than 0.3%
(test tape: WS-48B)
3.
Mode: Playback
test tape
P-4-A100
(10kHz, –10dB)
oscilloscope
set
Waveform of oscilloscope
in phase
45
°
90
°
135
°
180
°
good
wrong
Pin
6
(GND)
MAIN board
CN322
Pin
5
or TP42 (L-CH)
Pin
9
or TP46 (R-CH)
L
R
Record Bias Adjustment
Procedure:
INTRODUCTION
When set to the test mode performed in
Tape Speed Adjustment
,
when the tape is rewound after recording, the “REC memory mode”
which rewinds only the recorded portion and playback is set.
This “REC memory mode” is convenient for performing this
adjustment. During recording, the input signal FUNCTION will
automatically switch to MD.
(After recording, turn the
m/M
knob without stopping will
return to the position where recording was started.)
1.
Press FUNCTION button to select MD. (This step is not
necessary if the above test mode has already been set.)
2.
Insert a tape into deck, press the REC PAUSE/START button,
and then press the
Y
button to start recording.
3.
Mode: Record
5.
Confirm playback the signal recorded in step 2 become
adjustment level as follows.
If these levels do not adjustment level, adjust the RV653 (L-CH)
and RV603 (R-CH) on the TC board to repeat steps 3 and 4.
Adjustment level: The playback output of 10 kHz level difference
against 315 Hz reference should be 0 ± 0.5 dB.
[TC BOARD]
4.
Mode: Playback
recorded
position
level meter
set
MAIN board
CN322
Pin
5
or TP42 (L-CH)
Pin
9
or TP46 (R-ch)
AF OSC
MD IN
1) 315 Hz
2) 10 kHz
blank tape
CS-123
set
attenuator
600
Ω
} 50 mV (–23.8 dB)
Adjustment Location:
[MAIN BOARD]
RV652
(L-CH)
RV602
(R-CH)
RV653
(L-CH)
RV603
(R-CH)
Record Level
Record Bias
CN322
TP42
TP46
1
11
Содержание hcd-tb20
Страница 20: ...20 HCD TB20 3 19 IN OUT SW Board 2 two screws BTTP M2 6 3 IN OUT SW board 1 connector CN704 ...
Страница 38: ...38 38 HCD TB20 7 9 Schematic Diagram MAIN Section 3 3 Page 48 Page 34 Page 32 47p 47p 47p ...
Страница 40: ...40 40 HCD TB20 7 11 Schematic Diagram DECK Section TAPE DECK Page 36 22k 22k 1k See page 50 for Waveforms ...
Страница 42: ...42 42 HCD TB20 7 13 Schematic Diagram AMP Section Page 36 Page 36 Page 44 Page 46 c E MX E MX ...
Страница 48: ...48 48 HCD TB20 7 19 Schematic Diagram POWER Section I Page 38 Page 46 Page 46 ...
Страница 71: ...71 HCD TB20 MEMO ...