HCD-GTR33/GTR55/GTR77
11
SECTION 3
TEST MODE
PANEL TEST MODE
This mode is used to check the
fl
uorescent indicator tube, LEDs,
keys, [MASTER VOLUME] jog, [OPERATION DIAL] jog, mod-
el, destination and software version.
Procedure:
1. Press [
x
] button, [METER MODE] button and [DISC SKIP/
EX-CHANGE] button simultaneously.
2. All LEDs and segments in
fl
uorescent indicator tube are light-
ed up.
3. When you want to enter to the software version display mode,
press [DISC 1] button. The model information appears on the
fl
uorescent indicator tube.
• “GVX 1S” is shown for MHC-GTR33.
• “GVX 3S” is shown for MHC-GTR55.
• “GVX 4S” is shown for MHC-GTR77.
Press [DISC 1] button again to view the destination informa-
tion.
4. During the destination information display, press [DISC 1]
button. Each time [DISC 1] button is pressed, the
fl
uorescent
indicator tube shows the version of each category software in
the following sequence: SC, MTK (DMB Board
fi
rmware ver-
sion), GC, SYS, CD, CDMA, CDMB, ST, TC TA, TM , MTR
(METER) and return back to model information display.
5. When [DISC 3] button is pressed while the version numbers
are being displayed except model and destination, the date
of the software creation appears. When [DISC 3] button is
pressed again, the display returns to the software version dis-
play. When [DISC 1] button is pressed while the date of the
software creation is being displayed, the date of the software
creation is displayed in the same order of software version dis-
play.
6. Press [DISC 2] button, the key check mode is activated.
7. In the key check mode, the
fl
uorescent indicator tube displays
“K 0 V0”.
Each time a button is pressed, “K” value increases. However,
once a button has been pressed, it is no longer taken into ac-
count.
“V” value increases in the manner of 0,1, 2, 3 ... if [MASTER
VOLUME] knob is turned clockwise, or it decreases in the
manner of 0, 9, 8,7 ... if [MASTER VOLUME] knob is turned
counterclockwise.
8. When [DISC SKIP/EX-CHANGE] button is pressed after all
LEDs and segments in
fl
uorescent indicator tube light up, al-
ternate segments in
fl
uorescent indicator tube and LEDs would
light up. If you press [DISC SKIP/EX-CHANGE] button
again, another half of alternate segments in
fl
uorescent indi-
cator tube and LEDs would light up. Pressing [DISC SKIP/
EX-CHANGE] button again would cause all segments in
fl
uo-
rescent indicator tube and LEDs light up.
9. To release from this mode, press three buttons in the same
manner as step 1, or disconnect the power cord.
COMMON TEST MODE
This mode is used to check operations of the Ampli
fi
er section.
Procedure:
To enter Common Test Mode
1. Press [
x
] button, [METER MODE] button and [OPEN/
CLOSE] button simultaneously.
2. The CD ring indicators
fl
ash on the
fl
uorescent indicator tube.
The function is changed to AUDIO and the volume is changed
to VOLUME MIN.
Check of Ampli
fi
er
1. Press [EQ BAND/SURROUND] button repeatedly until a
message “GEQ MAX” appears on the
fl
uorescent indicator
tube. GEQ increases to its maximum.
2. Press [EQ BAND/SURROUND] button repeatedly until a
message “GEQ MIN” appears on the
fl
uorescent indicator
tube. GEQ decreases to its minimum.
3. Press [EQ BAND/SURROUND] button repeatedly until a
message “GEQ FLAT” appears on the
fl
uorescent indicator
tube. GEQ is set to
fl
at.
4. When the [MASTER VOLUME] knob is turned clockwise
even slightly, the sound volume increases to its maximum and
a message “VOLUME MAX” appears on the
fl
uorescent indi-
cator tube.
5. When the [MASTER VOLUME] knob is turned counterclock-
wise even slightly, the sound volume decreases to its minimum
and a message “VOLUME MIN” appears on the
fl
uorescent
indicator tube.
To release from Common Test mode
1. To release from this mode, press [
?/1
STANDBY] button.
2. The cold reset is enforced at the same time.
COLD RESET
The cold reset clears all data including preset data stored in the
EEPROM to initial conditions. Execute this mode when returning
the set to the customer.
Procedure:
1. Press
[
?/1
STANDBY] button to turn on the system.
2. Press
[
x
] button, [ENTER] button, and [
?/1
STANDBY] but-
ton simultaneously.
3. “COLD RESET” appears on the
fl
uorescent indicator tube.
After that, the
fl
uorescent indicator tube becomes blank for a
while, and the system is reset.
VACS ON/OFF
This mode is used to switch ON and OFF the VACS (Variable At-
tenuation Control System).
Procedure:
1. Press
[
?/1
STANDBY] button to turn on the system.
2. Press [
x
] button, [RETURN], and [DISPLAY] button simul-
taneously. The message “VACS OFF” or “VACS ON” appears
on the
fl
uorescent indicator tube.
TUNER STEP CHANGE
The step interval of AM channels can be toggled between 9 kHz
and 10 kHz.
Procedure:
1. Press
[
?/1
STANDBY] button to turn on the system.
2. Press [TUNER/BAND] button repeatedly to select the “AM”.
3. Press
[
?/1
STANDBY] button to turn off the system.
4. Press [ENTER] button and [
?/1
STANDBY] button simulta-
neously. The system turns on automatically. The message “AM
9K STEP” or “AM 10K STEP” appears on the
fl
uorescent
indicator tube and thus the channel step is changed.
CD SHIP MODE (WITH MEMORY CLEAR)
This mode moves the optical pick-up to the position durable to
vibration and clears all data including preset data stored in the EE-
PROM to initial conditions during the next AC-In. Use this mode
when returning the set to the customer after repair.
Procedure:
1. Press
[
?/1
STANDBY] button to turn on the system.
2. Select CD function.
3. Press [
x
] button, [OPEN/CLOSE] button and [
?/1
STAND-
BY] button simultaneously. The system turns off automati-
cally.
4. After the “STANDBY” blinking display
fi
nishes, a message
“MECHA LOCK” is displayed on the
fl
uorescent indicator
tube and the CD ship mode is set.