AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
IFT205
450 kHz
AM FREQUENCY COVERAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
IFT201
530 kHz
1.3
±
0.1 V
(531 kHz)
Confirmation
1,710 kHz
7.8
±
0.5 V
(1,602 kHz)
(7.1
±
0.5 V)
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
IFT202
603 kHz
VC205
1,404 kHz
FM FREQUENCY COVERAGE CONFIRMATION
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L204
87.5 MHz
2.3 to 2.5 V (1.4 to 1.6 V)
Confirmation
108 MHz
6.3 to 7.3 V (7.3 to 8.5 V)
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L203
90.1 MHz
VC202
106.1 MHz
TP
(FM ANT)
TP
(GND)
TP
(VT)
– MAIN BOARD (Conductor Side) –
– MAIN BOARD (Component Side) –
IFT205 AM IF Adjustment
L204 FM Frequency Coverage Adjustment
IFT201 AM Frequency Coverage Adjustment
L203
}
FM Tracking Adjustment
VC202
IFT202
}
AM Tracking Adjustment
VC205