18
HCD-DX30/RG40
Note :
Clear RF signal waveform means that the shape “
◊
” can be clearly
distinguished at the center of the waveform.
E-F Balance (1 Track jump) Check
Procedure :
1. Connect oscilloscope to TP (TEO) and TP (VC).
2. Turned Power switch on.
3. Load a disc (YEDS-18) and playback the number five track.
4. Press the
gG
button. (Becomes the 1 track jump mode.)
5. Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
6. After check, remove the lead wire connected in step 1.
RF PLL Free-run Frequency Check
Procedure :
1. Connect frequency counter to test point (XPCK) with lead wire.
2. Turned Power switch on.
3. Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218MHz.
RF signal waveform
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.45
±
0.3Vp-p
TP(TEO)
TP(VC)
BD board
oscilloscope
level=1.3
±
0.6Vp-p
symmetry
A (DC voltage)
center of
waveform
B
0V
1 track jump waveform
Specified level:
––
×
100=less than
±
22%
B
A
BD board
TP (XPCK)
frequency counter
TP
(XPCK)
TP
(TEO)
TP
(FEO)
TP
(FEI)
TP
(RF)
TP
(VC)
TP
(DGND)
TP
(AGCCON)
1
12
24
1
20
21
40
60
80
41
61
IC101
IC103
Adjustment Location:
[BD BOARD] (Conductor Side)