SAFETY CHECK-OUT
(US model only)
After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers).
Leakage current can be measured by any one of three methods.
1.
A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2.
A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3.
Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit” indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples of
a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2V AC range are suitable. (See
Fig. A)
Fig. A. Using an AC voltmeter to check AC leakage.
0.15
µ
F
To Exposed Metal
Parts on Set
1.5k
Ω
AC
voltmeter
(0.75V)
Earth Ground
Содержание HCD-BX7
Страница 20: ...20 MEMO ...
Страница 33: ...HCD BX7 DX7 DX7J 33 33 7 12 SCHEMATIC DIAGRAM POWER AMP SECTION DX7 DX7J MODEL Page 43 Page 43 Page 29 Page 29 ...
Страница 37: ...HCD BX7 DX7 DX7J 37 37 7 16 SCHEMATIC DIAGRAM LEAF SW SECTION Page 28 09 NORMAL SPEED HIGH SPEED ...
Страница 39: ...HCD BX7 DX7 DX7J 39 39 7 18 SCHEMATIC DIAGRAM DRIVER SECTION 09 Page 29 ...
Страница 43: ...HCD BX7 DX7 DX7J 43 43 7 22 SCHEMATIC DIAGRAM TRANS SECTION DX7 DX7J MODEL ...