— 6 —
SERVICE NOTE
1.
POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied (8.4V) to the battery terminal using the service power code (J-6082-223-A), the power
is shut off so that the unit cannot operate.
These following two methods are available to prevent this. Take note of which to use during repairs.
Method 1:
Connect the adjustment remote commander RM-95 (J-6082-053-B) to the LANC jack, and set the HOLD switch to the “ADJ” side.
Method 2:
Use the DC IN terminal. (Use the AC power adaptor. (AC-L10, AC-VQ800 etc.))
2.
TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT) (1)
1
Remove the power supply (Battery or AC power adaptor).
2
Push the EJECT switch and open the cassette lid.
3
Refer to 2-2. to remove the cabinet (lid) assembly.
4
Refer to 2-2. to remove the cabinet (bottom) assembly.
5
Add 5V from the regulated power supply between Pin
5
,
6
of CN4401 (ULD5V +) and Pin
7
,
8
of CN4401 (ULD5V –), and unload
the cassette.
Regulated
power supply (+5V)
VC-250 board
CN4401
1
ULD
5V
8
Содержание GV-D200E
Страница 11: ...1 2 ...
Страница 12: ...1 3 ...
Страница 13: ...1 4 ...
Страница 14: ...1 5 ...
Страница 15: ...1 6 ...
Страница 16: ...1 7 ...
Страница 17: ...1 8 ...
Страница 18: ...1 9 ...
Страница 19: ...1 10 ...
Страница 20: ...1 11 ...
Страница 21: ...1 12 ...
Страница 22: ...1 13 ...
Страница 23: ...1 14 ...
Страница 24: ...1 15 ...
Страница 25: ...1 16 ...
Страница 26: ...1 17 ...
Страница 27: ...1 18 ...
Страница 28: ...1 19 ...
Страница 29: ...1 20 ...
Страница 30: ...1 21 ...
Страница 31: ...1 22 ...
Страница 32: ...1 23E ...
Страница 56: ...GV D200 D200E D800 D800E 4 9 REC PB AMP DAC DV I F Y C PROCESSOR LINE SERVO MECHA HI CONT D D CONV VC 250 ...
Страница 160: ...GV D200 D200E D800 D800E 206 9 929 853 11 Sony EMCS Co 2003F1600 1 2003 6 Published by DI CS Strategy Div ...
Страница 165: ... 8 GV D200 D200E D800 D800E Sony EMCS Co 2002C1600 1 2002 3 Published by DI Customer Center 9 929 853 81 ...