2-5. H/V CENTER CONFIRMATION AND ADJUSTMENTS
Please check the picture horizontal/vertical center after the replacement of the Optics Unit Block Assembly or any part of the Top assembly.
1. Check the H/V center with 480i monoscope signal in “Full” mode.
2. If the center is shifted, adjust using the following service items:
NOTE: Please record the steps shifted as MDHP and MDVP .
����
����
�����������������������������
�����������������������
3. Change the WIDE mode to “Normal” and change the register data as follows:
MID-X1 9 MDHP + MDHP
(Don't change the MDVP data)
4. Display the Twin Picture with the “split” button of the remote commander and change the registers data as follows:
MID-X1 9 MDHP + MDHP
10 MDVP + MDVP
5. Press “Favorites” button and change the registers data as follows:
���������������������������
�������������������
6. OSD horizontal position must be adjusted as follows:
If above sum exceeds 255, set 1 to “16 RP1H” and set the “sum-256” to “17 RP1L”.
Since the registers are different from other cases, be careful to follow complete instructions, and write the data before changing the display/