-38-
Error code table
Suspected faulty board
(In the order of higher probability of defect)
ERR
code
Detect
position
(board)
Contents
(1)
(2)
(3)
(4)
(5)
(6)
(7)
Remarks
00
LOGIC
STANDBY power is stopped
PSU
PSU temperature
has probably
increased
02
ROM data of waveform is abnormal LOGIC
04
3.3V power voltage has dropped
LOGIC
PSU
06
3.3V power startup is faulty
X-SUS
Y-SUS
ADMU1-U11
ADND1-D11
PSU
ABUSU1-U4
ABUSD1-D4
LOGIC
08
1V power voltage has dropped
LOGIC
PSU
0A
1V power startup is faulty
X-SUS
Y-SUS ADM1-22 PSU
ABUS
LOGIC
18
Internal
I2C_SCL1_LOW
level
LOGIC
19
Internal I2C_ACK does not respond LOGIC
1C
EEPROM initial setting is defective LOGIC
1D
EEPROM write-down is defective
LOGIC
1E
EEPROM user initial setting is
defective
LOGIC
1F
LOGIC
EEPROM factory setting reading is
defective
LOGIC
24
Vex power voltage has decreased
X-SUS
LOGIC
25
Vex power voltage is excessive
X-SUS
26
Vex power startup is faulty.
X-SUS
LOGIC
28
Vx power voltage has dropped
X-SUS
LOGIC
29
Vx power voltage is excessive
X-SUS
2A
Vx power startup is faulty.
X-SUS
LOGIC
39
Vs power current is excessive
(during operation)
X-SUS Panel LOGIC
3B
Vs power current is excessive
(during startup)
X-SUS Panel LOGIC
3C
Vq power voltage has dropped
X-SUS
3D
Vq power voltage is excessive
X-SUS
3E
X-SUS
Vq power startup is faulty.
X-SUS
44
Vey power voltage has dropped
Y-SUS
LOGIC
45
Vey power voltage is excessive
Y-SUS
46
Vey power startup is faulty.
Y-SUS
LOGIC
48
Vu power voltage has dropped
Y-SUS
49
Vu power voltage is excessive
Y-SUS
4A
Vu power startup is faulty.
Y-SUS
59
Vs power current is excessive
(during operation)
Y-SUS Panel LOGIC
5B
Vs power current is excessive
(during startup)
Y-SUS Panel LOGIC
5D
Y-SUS
SDM current is excessive
SDM
Y-SUS Panel
LOGIC
61
Vs power voltage is excessive
PSU
X-SUS LOGIC
62
Vs power startup is faulty.
X-SUS
Y-SUS PSU
LOGIC
64
Ve power voltage has dropped
LOGIC
X-SUS Y-SUS
65
Ve power voltage is excessive
X-SUS
Y-SUS
66
Ve power startup is faulty.
LOGIC
X-SUS Y-SUS
68
Vw power voltage has dropped
Y-SUS
X-SUS LOGIC
69
Vw power voltage is excessive
X-SUS
6A
X-SUS
Y-SUS
Vw power startup is faulty.
Y-SUS
X-SUS LOGIC
81
Va power voltage is excessive
PSU
X-SUS LOGIC
82
Va power startup is faulty.
ADMU1-U11
ADND1-D11
PSU X-SUS LOGIC
ABUS
99
Va power current is excessive
(during operation)
ADMU1-U11
ADND1-D11
ABUS
X-SUS PSU LOGIC
9B
ABUS
Va power current is excessive
(during startup)
ADMU1-U11
ADND1-D11
ABUS
X-SUS PSU LOGIC