14 —
KV-36FS12/36FS16/36FV16/36FV26
10
9
8
7
1
6
5
4
3
2
Coated
Earth
Ground
Strap
2-4. PICTURE TUBE REMOVAL
WARNING:
BEFORE REMOVING
THE ANODE CAP
High voltage remains in the CRT
even after the power is discon-
nected. To avoid electric shock,
discharge CRT before attempting
to remove the anode cap. Short
between anode and CRT coated
earth ground strap.
a
REMOVAL PROCEDURES
HOW TO HANDLE AN ANODE CAP
WARNING: High voltage remains in the CRT even after the power is disconnected. To avoid electrical shock, discharge the CRT before
attempting to remove the anode cap. Short between anode and coated earth ground strap of CRT.
NOTE:
After removing the anode, short circuit the anode of the picture tube and the anode cap to either the metal chassis, CRT shield,
or carbon painted on the CRT.
1
Do not use sharp objects which may cause damage to the
surface of the anode cap.
3
Do not force turn the foot of the rubber cover. This may cause
the shatter-hook terminal to protrude and damage the rubber.
2
To avoid damaging the anode cap, do not squeeze the rubber
covering too hard. A material fitting called a shatter-hook terminal
is built into the rubber.
2
Use your thumb to pull the rubber
cap firmly in the direction indicated
by arrow
b
.
3
When one side of the rubber cap
separates from the anode button,
the anode cap can be removed by
turning the rubber cap and pulling
it in the direction of arrow
c
.
1
Turn up one side of the rubber cap in
the direction indicated by arrow
a
.
b
Anode Button
c
ANODE CAP REMOVAL
1. Discharge the anode of the CRT and remove the anode cap.
2. Unplug all interconnecting leads from the deflection yoke, neck
assembly, degaussing coils and CRT grounding strap.
3. Remove the C Board from the CRT.
4. Remove the chassis assembly.
5. Loosen the neck assembly fixing screw and remove.
6. Loosen the deflection yoke fixing screw and remove.
7. Place the set with the CRT face down on a cushion and remove
the degaussing coil holders.
8. Remove the degaussing coils.
9. Remove the CRT grounding strap and spring tension devices.
10. Unscrew the four CRT fixing screws [located on each CRT
corner] and remove the CRT [Take care not to handle the CRT
by the neck].
Содержание FD Trinitron WEGA KV-36FS12
Страница 9: ... 9 KV 36FS12 36FS16 36FV16 36FV26 ...
Страница 10: ... 10 KV 36FS12 36FS16 36FV16 36FV26 ...
Страница 11: ... 11 KV 36FS12 36FS16 36FV16 36FV26 ...
Страница 12: ... 12 KV 36FS12 36FS16 36FV16 36FV26 ...
Страница 30: ... 30 KV 36FS12 36FS16 36FV16 36FV26 NOTES ...
Страница 47: ...KV 36FS12 36FS16 36FV16 36FV26 WA BOARD SCHEMATIC DIAGRAM 75 76 ...
Страница 87: ... 117 NOTES KV 36FS12 36FS16 36FV16 36FV26 ...
Страница 88: ... 118 NOTES KV 36FS12 36FS16 36FV16 36FV26 ...
Страница 89: ... 119 KV 36FS12 36FS16 36FV16 36FV26 ...