— 25 —
KV-20FS12/20FV12/21FE12/A/C/21FM12/21FV12/C
H. Center Adjustment (HPOS)
Perform this adjustment after performing H. Frequency
(Free Run) Check.
1. Input a crosshatch signal.
2. Activate the Service Adjustment Mode.
3. Select the HPOS item with
and
.
4. Adjust the value of HPOS with
and
for the best
horizontal center.5.
Press
then
to save into the memory.
H. Size Adjustment (HSIZ)
1. Input a monoscope signal.
2. Activate the Service Adjustment Mode.
3. Select HSIZ with
and
.
4. Adjust with
and
for the best horizontal size.
5. Press
then
to save into the memory.
V. Linearity (VLIN), V. Correction (VSCO),
Pin Amp (PAMP), and Horizontal Trapezoid
(TRAP) Adjustments
1. Input a crosshatch signal.
2. Activate the Service Adjustment Mode.
3. Select VLIN, VSCO, PAMP, and PPHA with with
and
.
4. Adjust with
and
for the best horizontal size.
5. Press
then
to save into the memory.
V LINEARITY (VLIN)
V CORRECTION (VSCO)
PIN AMP (PAMP)
HORIZONTAL TRAPEZOID (TRAP)
9. Select the DCOL item and reset to 1.
10. Press
then
to save into the memory.
V. Size Adjustment (VSIZ)
1. Input a crosshatch signal.
2. Activate the Service Adjustment Mode.
3. Select the VSIZ item with
and
.
4. Adjust value of VPOS with
and
for the best vertical
center.
5. Press
then
to save into the memory.
V. Center Adjustment (VPOS)
Perform this adjustment after performing H. Frequency
(Free Run) Check.
1. Input a crosshatch signal.
2. Activate the Service Adjustment Mode.
3. Select the VPOS item with
and
.
4. Adjust value of VPOS with
and
for the best vertical
center.
5. Press
then
to save into the memory.
Содержание FD TRINITRON WEGA KV-20FS12
Страница 53: ... 71 KV 20FS12 20FV12 21FE12 A C 21FM12 21FV12 C ...
Страница 73: ... 19 KV 20FS12 20FV12 21FE12 A C 21FM12 21FV12 C ...