57
Command List
Digital Zoom Combine mode
X12-NTSC/PAL
Digital Zoom
Digital Zoom
Ratio
Position Data
×
1
4000
×
2
6000
×
3
6A80
×
4
7000
×
5
7300
×
6
7540
×
7
76C0
×
8
7800
×
9
78C0
×
10
7980
×
11
7A00
×
12
7AC0
Digital Zoom Separate mode
Lens control
Zoom Position
0000
to
4000
to 7AC0
Wide end
Optical
Digital
Tele end
Tele end
Focus Position
1000
to
C000
Far end
Near end
1000: Over Inf
2000: 8 m
3000: 3.5 m
4000: 2 m
As the distance on the left
Focus Near
5000: 1.4 m
will differ due to temperature
Limit
6000: 1 m
characteristics, etc., use as
7000: 80 cm
approximate values.
8000: 29 cm
* The lower 1 byte is fixed at
9000: 10 cm
00.
A000: 4.7 cm
B000: 2.3 cm
C000: 1 cm
Temperature Reading Conversion Value
(Reference Value)
Line number
00 to 0A
H-position
00 to 17
Blink
00: Dose not blink
01: Blinks
00
White
01
Yellow
02
Violet
Color
03
Red
04
Cyan
05
Green
06
Blue
00
01
02
03
04
05
06
07
A
B
C
D
E
F
G
H
08
09
0a
0b
0c
0d
0e
0f
I
J
K
L
M
N
O
P
10
11
12
13
14
15
16
17
Q
R
S
T
U
V
W
X
18
19
1a
1b
1c
1d
1e
1f
Y
Z
&
?
!
1
2
20
21
22
23
24
25
26
27
3
4
5
6
7
8
9
0
28
29
2a
2b
2c
2d
2e
2f
À
È
Ì
Ò
Ù
Á
É
Í
30
31
32
33
34
35
36
37
Ó
Ú
Â
Ê
Ô
Æ
Œ
Ã
38
39
3a
3b
3c
3d
3e
3f
Õ
Ñ
Ç
ß
Ä
Ï
Ö
Ü
40
41
42
43
44
45
46
47
Å
$
F
¥
DM
£
¿
¡
48
49
4a
4b
4c
4d
4e
4f
ø
“
:
‘
.
,
/
-
Title setting
X12-NTSC/PAL
Digital Zoom
Digital Zoom
Ratio
Position Data
×
1
00
×
2
80
×
3
AA
×
4
C0
×
5
CC
×
6
D5
×
7
DB
×
8
E0
×
9
E3
×
10
E6
×
11
E8
×
12
EB
Reading Value
Temperature
pq (hex)
Conversion
Value (ºC)
00
–3 to +3
0A
7 to 13
14
17 to 23
1E
27 to 33
28
37 to 43
32
47 to 53
3C
57 to 63