Byte 1
Bit 7
(MSB)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
Byte 2
1
0
Byte 3
FF
Sender’s
address
Receiver’s
address
Bit 7
(MSB)
Packet (3 to 16 bytes)
Message (1 to 14 bytes)
Header
Terminator
Bit 6 Bit 5 Bit 4 Bit 3
Bit 2
Bit 1 Bit 0
(LSB)
1
1
1
1
1
1
1
1
VISCA™ Communication Specifications
VISCA™ packet structure
The basic unit of VISCA™ communication is called packet (Fig. 3). The first byte of the packet is called header and
comprises the sender’s and receiver’s addresses. For example, the header of the packet sent to the FCB camera of address 1
from the controller of address 0 is hexadecimal 81H. The packet sent to the FCB camera of address 2 is 82H. In the command
list, as the header is 8X, input the address of the FCB camera at X. The header of the reply packet from the FCB camera of
address 1 is 90H. The packet from the FCB camera of address 2 is A0H.
Some of the commands for setting the FCB camera can be sent to all devices at one time (broadcast). In the case of broadcast,
the header should be hexadecimal and 88H.
When the terminator is FFH, it signifies the end of the packet.
Fig. 3 Packet structure
Command and inquiry
Command: Commands operations to the FCB camera.
Inquiry
: Used for examining the state of the FCB camera.
Command Packet
Note
Inquiry
8X QQ RR ... FF
QQ = Command/Inquiry, RR = category code*
*QQ = 01 (Command), 09 (Inquiry)
*RR = 00 (Interface), 04 (camera 1), 06 (Pan/Tilter), 07 (Camera 2)
*X = 1 to 7: FCB camera address
VISCA™/RS-232C
Содержание FCB-IX47
Страница 1: ...Instruction Manual Ver 1 01 English COLOR CAMERA MODULE FCB IX47 IX47P FCB IX470 IX470P ...
Страница 4: ...2 FCB IX47 IX47P FCB IX470 IX470P DIMENSIONS Unit mm FCB IX47 IX47P FCB IX470 IX470P Unit mm ...
Страница 18: ...16 FCB IX47 IX47P FCB IX470 IX470P INSTALLATION To fix the camera 1 4 20UNC or 4 of M2 is used Unit mm ...
Страница 25: ...23 Command List Ver 1 0 English ...
Страница 50: ...48 FCB IX47 IX47P FCB IX470 IX470P MEMO ...
Страница 51: ...Sony reserves the right to change specifications of the products and discontinue products without notice ...