7
ICF-C218
SECTION 3
ELECTRICAL ADJUSTMENTS
AM Section
0dB=1
µ
V
Procedure :
BAND
: AM
VOLUME
: 10mW
FM Section
Procedure :
BAND
: FM
VOLUME
: 10mW
• Repeat the procedures in each adjustment several times, and
the frequency coverage and tracking adjustments should be
finally done by the trimmer capacitors.
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455kHz
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520kHz
CT1-4
1,750kHz
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
620kHz
CT1-1
1,400kHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
86.5MHz
CT1-3
109.5MHz
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
confirm
86.5MHz
CT1-2
109.5MHz
TUNER SECTION
AM RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to
the set.
FM RF signal
generator
22.5kHz frequency deviation by
400Hz signal.
Output level : as low as possible
antenna
terminal
TP1(RF IN)
0.01
µ
F
set
8
Ω
speaker terminal
level meter
Содержание Dream Machine ICF-C218
Страница 15: ...15 ICF C218 MEMO ...