1-3
DCR-VX2200E_L2
1-5-3. Self-diagnosis Code Table
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
Block
Function
0
4
0
6
2
1
2
2
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
Detailed
Code
0
0
0
0
0
0
0
0
1
0
1
1
2
0
2
1
2
2
2
3
2
4
3
0
4
0
4
2
7
2
9
7
9
8
9
9
1
0
1
1
2
0
2
1
2
2
2
3
2
4
3
0
4
0
4
2
6
0
Symptom/State
Non-standard battery is used.
The battery is too hot.
Condensation.
Video head is dirty.
LOAD direction. Loading does not
complete within specified time
UNLOAD direction. Loading does not
complete within specified time
T reel side tape slacking when unloading.
S reel side tape slacking when unloading.
T reel fault.
S reel fault.
T reel and S reel FG short fault.
FG fault when starting capstan.
FG fault when starting drum.
FG fault during normal drum operations.
Retry fault when catching one’s finger
in cassette compartment.
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
LOAD direction loading motor time-
out.
UNLOAD direction loading motor
time-out.
T reel side tape slacking when
unloading.
S reel side tape slacking when
unloading.
T reel fault.
S reel fault.
T reel and S reel FG short fault.
FG fault when starting capstan.
FG fault when starting drum.
FG fault during normal drum
operations.
Difficult to adjust focus
(Cannot initialize focus.)
Self-diagnosis Code
Repaired b
y:
Correction
Use the InfoLITHIUM battery.
Replace the battery or remove it and put it in cool place.
Remove the cassette, and insert it again after one hour.
Clean with the optional cleaning cassette.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
If it does not recover, inspect the focus MR sensor of lens drive
block (Pin
q;
,
qs
of CN5002 on the VC-597 board).
If not faulty, inspect the focus motor drive circuit
(IC6001 on the VC-597 board).