5-17
3. Flange Back Adjustment
(Using Flange Back Adjustment Chart Subject More
Than 500 m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
3-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the lens)
(Luminance: 350 ± 50 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
4E to 5D, 61
Note :
Perform this adjustment after performing “HALL adjustment”.
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Check that at both the zoom lens TELE end and WIDE end,
the center of the chart for the flange back adjustment and center
of the exposure screen coincide.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 6, address: 82, and set data: 01.
4)
Check that the data of page: F, address: 4E to 5D, 61 is the
initial value (See table below).
5)
Select page: 6, address: 02, and check that the data is “00”.
6)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 6, address: 01, set data: 15, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses:4E to 5D, 61)
8)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments
1)
Turn OFF the main power supply (8.4 V).
2)
Perform “Flange Back Adjustment (2)”.
3-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
4E to 5D, 61
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500 m away should
not be in the screen.)
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 6, address: 82, and set data: 01.
4)
Select page: 6, address: 02, and check that the data is “00”.
5)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
6)
Place a ND filter on the lens so that the optimum image is
obtain.
7)
Select page: 6, address: 01, set data: 29, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses: 4E to 5D, 61)
8)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments
1)
Select page: 0, address: 01, and set data: 00.
2)
Turn OFF the main power supply (8.4 V).
3)
Perform “Flange Back Check”.
Address
4E
4F
50
51
52
53
54
55
56
Data
2E
12
48
F1
18
5D
66
00
19
Address
57
58
59
5A
5B
5C
5D
61
Data
00
19
00
00
04
00
00
00
Содержание DCR-TRV120P
Страница 13: ...1 2 ...
Страница 14: ...1 3 ...
Страница 15: ...1 4 ...
Страница 16: ...1 5 ...
Страница 17: ...1 6 ...
Страница 18: ...1 7 ...
Страница 19: ...1 8 ...
Страница 20: ...1 9 ...
Страница 21: ...1 10 ...
Страница 22: ...1 11 ...
Страница 23: ...1 12 ...
Страница 24: ...1 13 ...
Страница 25: ...1 14 ...
Страница 26: ...1 15 ...
Страница 27: ...1 16 ...
Страница 28: ...1 17 ...
Страница 29: ...1 18 ...
Страница 30: ...1 19 ...
Страница 31: ...1 20 ...
Страница 32: ...1 21 ...
Страница 33: ...1 22 ...
Страница 34: ...1 23 ...
Страница 35: ...1 24 ...
Страница 36: ...1 25 ...
Страница 37: ...1 26 ...
Страница 38: ...1 27 1 27 E ...
Страница 84: ...DCR TRV120 TRV120E TRV120P TRV125E TR8000E TR8100E 4 61 4 62 USER CONTROL CF 69 ...
Страница 88: ...DCR TRV120 TRV120E TRV120P TRV125E TR8000E TR8100E 4 69 4 70 USER CONTROL CF 71 ...