1-1
ENGLISH
ENGLISH
DSC-W220_L2
1. SERVICE NOTE
1-1. PRECAUTION ON REPLACING THE SY-214 BOARD
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATON DATA WRITE”.
RESTORE DATA
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “RESTORE DATA” to get the data.
The data getting for this model is as follows.
• USB SERIAL No.
• Angular Velocity Sensor
USB SERIAL No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Start the Adjust Manual in the Adjust Station and execute the “USB SERIAL No. INPUT”.
Angular Velocity Sensor
When you replace to the reparing board, write down the sensitivity displayed on the angular velocity sensor (SE401 and SE402).
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity adj”.
Note:
The sensor sensitivity of SE401 and SE402 of SY-214 board is written only repair parts.
1-2. PRECAUTION ON REPLACING THE LENS
When replacing the lens, write down the PITCH/YAW data given on the data sheet of the replacement lens for service.
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity adj”.
Note:
The PITCH/YAW data of lens are written only repair parts.
PP
YY
PP:
PITCH Sensor
sensitivity
YY:
YAW Sensor
sensitivity
SE401
SE402
SY-214 BOARD (SIDE B)
1
1
2
4
3
2
4
3
P.PP/ Y
.YY
YAW data
PITCH/YAW Data
PITCH data
P.PP / Y.YY