DSC-W1/W12
6-25
1-7.
INITIALIZATION OF DATA
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note:
If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click
[Sector Write]
on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “0A”.
4) Click
[All]
of the ALL SELECT buttons to select all pages.
(Fig. 6-1-56
A
)
5) Click
[Write]
to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click
[Close]
to close the SEUS SECTOR WRITE screen.
8) Select page: 8E, address: 00 and set data: 20.
9) Click
[Save]
on the SEUS screen.
10) Wait for more than 3 sec.
11) Select page: 80, address: 30, and check that the data is “00”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
20
00
29
[Set]
2
20
01
29
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click
[Connect]
on the SEUS screen to restore
the “connected” state. (In case that the power does not turn
on again, press the power button.)
Fig. 6-1-56
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1:
If the 6D or 6E or 6F page data have been initialized, the
following adjustment needs to be performed again.
1) Camera system adjustments
Note 2:
If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click
[Sector Write]
on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “0A”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-56
B
)
5) Click
[Write]
to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click
[Close]
to close the SEUS SECTOR WRITE screen.
8) When 8E page is initialized, select page: 8E, address: 00 and
set data: 20.
9) Click
[Save]
on the SEUS screen.
10) Wait for more than 3 sec.
11) Select page: 80, address: 30, and check that the data is “00”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
20
00
29
[Set]
2
20
01
29
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click
[Connect]
on the SEUS screen to restore
the “connected” state. (In case that the power does not turn
on again, press the power button.)
B
A
0A