1-2E
DSC-M1
Note :
The error code is cleared if the battery is removed, except defective flash unit.
*1: The error display is given in two ways.
Display Code
C:32:01
C:13:01
E:91:01
E:01:XX
E:61:00 *1
E:61:10 *1
Countermeasure
Turn off the main power then back on.
Replace the memory stick.
Format the memory stick with the DSC-M1.
Checking of flash unit or replacement of
flash unit.
Checking of lens drive circuit
Cause
Trouble with hardware.
• The type of memory stick that cannot be
used by this machine, is inserted.
• Data is damaged.
• Unformatted memory stick is inserted.
Abnormality when flash is being
charged.
When failed in the focus initialization.
Caution Display During Error
SYSTEM ERROR
MS ERROR
Flash LED
Flash display
Flashing at 3.2 Hz
—
Self-diagnosis display
• C:
ss
:
ss
The contents which can be handled
by customer, are displayed.
• E:
ss
:
ss
The contents which can be handled
by engineer, are displayed.
[Description on Self-diagnosis Display]
Содержание Cyber-shot DSC-M1
Страница 53: ...ENGLISH JAPANESE ENGLISH JAPANESE ...