1-5E
DSC-H20_L2
1-5-3. Self-diagnosis Code Table
C
C
E
E
E
E
E
E
E
E
E
Block
Function
1
3
3
2
6
1
6
1
6
2
6
2
6
2
6
2
6
2
9
1
9
2
Detailed
Code
0
1
0
1
0
0
1
0
0
2
1
0
1
1
1
2
2
0
0
1
0
0
Symptom/State
The internal memory has experienced a
media error.
The internal memory has experienced a
format error.
“Memory Stick Duo” is unformatted.
“Memory Stick Duo” is broken.
“Memory Stick Duo” type error
The camera cannot read or write data
on the “Memory Stick Duo”.
Trouble with hardware
Difficult to adjust focus
(Cannot initialize focus)
Zoom operations fault
(Cannot initialize zoom lens.)
Abnormality of IC for steadyshot.
Lens initializing failure.
Lens overheating (PITCH).
Lens overheating (YAW).
Abnormality of thermistor.
Abnormality when flash is being charged.
Non-standard battery is used.
Self-diagnosis Code
Repaired b
y:
Correction
Turn the power off and on again.
Format the internal memory.
Format the “Memory Stick Duo”.
Insert a new “Memory Stick Duo”.
Insert a supported “Memory Stick Duo”.
Turn the power off and on again, or taking out and inserting the
“Memory Stick Duo” several times.
Turn the power off and on again.
Retry turn the power on by the power switch. If it does not
recover, check the focus reset sensor of lens block (pin
wj
of
CN402 on the SY-224 board). If it is OK, check the focus motor
drive IC (IC401 on the SY-224 board).
Retry turn the power on by the power switch. Check the zoom
reset sensor of lens block (pin
qj
of CN402 on the SY-224
board), if zooming is performed when the zoom lever is
operated. If it is OK, check the zoom motor drive IC (IC401 on
the SY-224 board).
Check or replacement of the IC for steadyshot (IC401 on the SY-
224 board).
Check or replacement of the IC for steadyshot (IC401 on the SY-
224 board).
Check the HALL element (PITCH) of optical image stabilizer
(pin
3
,
2
of CN401 on the SY-224 board). If it is OK, check
PITCH/YAW angular velocity sensor (SE401 on the SY-224
board) peripheral circuits.
Check the HALL element (YAW) of optical image stabilizer (pin
6
,
7
of CN401 on the SY-224 board). If it is OK, check
PITCH/YAW angular velocity sensor (SE401 on the SY-224
board) peripheral circuits.
Check the OIS temp sensor of optical image stabilizer (pin
ql
,
w;
of CN402 on the SY-224 board).
Checking of flash unit or replacement of flash unit. (Note)
Use the compatible battery only.
Note:
After repair, be sure to perform “1-6. PROCESS AFTER FIXING FLASH ERROR”.
1-6. PROCESS AFTER FIXING FLASH ERROR
When “FLASH error” (Self-diagnosis Code E : 91 : 01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash
is changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Flash error code can be initialized by the operations on the HOME screen.
Method for Initializing the Flash Error Code
Initializes the setting to the default setting.
Even if you execute this function, the images are retained.
1
MENU
t
(Settings)
t
(Main Settings)
t
[Initialize]
t
[OK]
t
z
on the control button
•
Be sure not to turn off the camera while initializing.
Note
The changed portions from
Ver. 1.0 are shown in blue.
Содержание Cyber-shot DSC-H20
Страница 28: ...DSC H20_L2 Schematic diagram of the SY 224 board is not shown Pages from 4 4 to 4 12 are not shown ...
Страница 36: ...DSC H20_L2 Printed wiring board of the SY 224 board is not shown Page 4 20 is not shown ...
Страница 57: ...HARDWARE LIST 9 9 3 0 1 4 161 M1 4 X 3 0 Black 4 139 852 01 ...