5-10
2.
G-CAM Flip Adjustment
Set the color reproduction conditions to optimum.
Subject
Color bar chart standard picture
frame
Measurement Point
DDS displayed data of TV
Measuring Instrument
monitor (Note 1)
Adjustment Page
F
Adjustment Address
21
Note 1:
The right four digits of the displayed data at the right
bottom side of the TV monitor.
00 XXXX
→
S
2
→
S
1
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 11, and set data: 02, and press the
PAUSE button of the adjusting remote commander.
3) Select page: 0, address: 03, and set data: 16.
4) Read the DDS displayed data (Note 1), and upper two digits
data is named S
1
, and lower two digits data is named S
2
.
When S
1
<S
2
Perform steps 5) onwards.
When S
1
>S
2
Perform steps “Processing after Completing Adjustments”.
5) Select page: F, address: 21, and set data:
when the read data is “D2”, change to “52”, the read data is
“52”, change to “D2” (initial value is 52), and press the PAUSE
button of the adjusting remote commander.
Processing after Completing Adjustments:
1) Select page: 0, address: 03, and set data: 00.
2) Select page: D, address: 11, and set data: 00, and press the
PAUSE button
of the adjusting remote commander.
3) Select page: 0, address: 01, and set data: 00.
=
5-4.
CAMERA SYSTEM ADJUSTMENT
Before perform the camera system adjustments, check that the
specified value of
“Y OUT Level Adjustment”, “C OUT Level Adjustment” and
“28MHz Origin Oscillation Adjustment” of “ELECTRICAL AD-
JUSTMENTS” are satisfied.
1.
Lens Type Adjustment
Judge whether the lens used in the set is a plastic or glass, then
enter the data according to the lens material.
Subject
Not required
Measurement Point
DDS displayed data of TV
Measuring Instrument
monitor (Note 1)
Adjustment Address
Page: E, Address: 2B to 2E
Page: F, Address: 26
Note 1:
The right two digits of the displayed data at the right
bottom side of the TV monitor.
00 00XX
→
D
1
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 11, and set data: 02, and press the
PAUSE button of the adjusting remote commander.
3) Select page: 0, address: 03, and set data: 19.
4) Select page: 2, address: 01, and set data: 65.
5) Read the DDS displayed data (Note 1), and take the lower two
digits as D
1
.
When D
1
= 00 (glass lens)
Perform steps 6) onwards.
When D
1
= 01 (plastic lens)
Perform steps “Processing after Completing Adjustments”.
6) Write data in page: E, address: 2B to 2E, and page: F, address:
26 as shown in the following table.
Processing after Completing Adjustments:
1) Select page: 2, address: 01, and set data: 00.
2) Select page: 0, address: 03, and set data: 00.
3) Select page: D, address: 11, and set data: 00, and press the
PAUSE button of the adjusting remote commander.
4) Select page: 0, address: 01, and set data: 00.
Page
Address
Data
E
2B
11
E
2C
83
E
2D
FB
E
2E
F5
F
26
96