CMT-X3CD
17
2-11. FV BOARD
4
flexible flat cable (10P)
(XP7)
1
connector
(XP17)
5
two screws
(5)
2
two claws
2
two claws
6
FV board
colored line
Insert straight into the interior.
flexible flat
cable
connector
OK
colored line
Insert at a slant.
flexible flat
cable
connector
NG
Note:
When installing the flexible flat cable, ensure that
the colored line is parallel to the connector after insertion.
– Front bottom view –
3
Remove the FV board block
in the direction of the arrow.
Ver. 1.1