Focus Bias Adjustment
This adjustment is to be done when the optical pick-up is replaced.
Procedure:
1. Connect the oscilloscope IC701 pin
#¡
and TP701 pin
2
on
the CD DECODER board.
2. Put the disc (YEDS-18.)
3. Put the set into test mode. (See page 20.)
4. Press
±
and
≠
buttons to move the optical pick-up to the
center. (Move the optical pick-up to the music area on the disc
to enable easy visibility of the eye pattern.)
5. Press the
fl
button.
From focus searching, focus is turned ON while entering
CLV drawing-in mode. Tracking and sled are turned OFF.
6. Press the
fl
button.
[Both tracking and sled are turned ON.]
7. Adjust VR701 so that the oscilloscope waveform is as shown in
the figure below. (eye pattern)
A good eye pattern means that the diamond shape (
◊
) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
8. Release the test mode after adjustment is completed.
Adjustment Location: CD DECODER board (See page 22.)
E-F Balance Adjustment
This adjustment is to be done when the optical pick-up is replaced.
Procedure:
1.
Connect the oscilloscope to TP702 pin
1
and pin
2
on the
CD DECODER board.
2.
Put the disc (YEDS-18).
3.
Put the set into test mode. (See page 20.)
4.
Press the
±
and
≠
buttons to move the optical pick-up to
the center.
5.
Press the
fl
button.
From focus searching, focus is turned ON while entering
CLV drawing-in mode. Tracking and sled are turned OFF.
6.
Adjust VR702 so that the oscilloscope traverse waveform is
symmetrical, as shown in the figure below.
Adjustment value: 0.3 to 0.7Vp-p (A+B)
7. Release the test mode after adjustment is completed.
Adjustment Location: CD DECODER board (See page 22.)
oscilloscope
(DC range)
CD DECODER board
TP702 pin
1
TP702 pin
2
0V
A
B
A=B
0V
A=B
A
B
VOLT/DIV: 0.2V (with the 10:1 probe in use.)
TIME/DIV:1ms
Note: Take long sweep time
for easy monitoring.
oscilloscope
(AC range)
CD DECODER board
IC701 pin
#¡
TP701 pin
2
VOLT/DIV : 0.2V (with the 10:1 probe in use.)
TIME/DIV : 500ns
0.8 to 1.8Vp-p
When observing the eye pattern, set the oscilloscope for AC
range and raise vertical sensitivity.