20
CFD-G505
SECTION 6
DIAGRAMS
For Schematic Diagrams.
Note:
• All capacitors are in
µ
F unless otherwise noted. (p: pF)
50 WV or less are not indicated except for electrolytics and
tantalums.
• All resistors are in
Ω
and
1
/
4
W or less unless otherwise
specified.
•
f
: internal component.
•
C
: panel designation.
•
A
: B+ Line.
•
H
: adjustment for repair.
• Total current is measured with no cassette installed.
• Power voltage is dc 12 V and fed with regulated dc power
supply from battery terminal.
• Voltages and waveforms are dc with respect to ground un-
der no-signal (detuned) conditions.
• Voltages are taken with a VOM (Input impedance 10 M
Ω
).
Voltage variations may be noted due to normal production
tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal production
tolerances.
• Circled numbers refer to waveforms.
• Signal path.
F
: FM
f
: AM
E
: PB
a
: REC
J
: CD
d
: LINE IN
For Printed Wiring Boards.
Note:
•
X
: parts extracted from the component side.
•
f
: internal component.
•
: Pattern from the side which enables seeing.
(The other layers' patterns are not indicated.)
• Indication of transistor.
THIS NOTE IS COMMON FOR PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS.
(In addition to this, the necessary note is printed in each block.)
Note: The components identified by mark
0
or dotted
line with mark
0
are critical for safety.
Replace only with part number specified.
Caution:
Pattern face side:
Parts on the pattern face side seen from
(Side B)
the pattern face are indicated.
Parts face side:
Parts on the parts face side seen from
(Side A)
the parts face are indicated.
C
B
These are omitted.
E
Q
B
These are omitted.
C
E
Q