37
CDX-5V661/5V661A/5V661D/5V661S
7. DIAG Mode
(See “Display List” on page 18 and 19)
This mode performs the following operation:
• Error history display
• 50 history data can be checked, starting from the latest data.
• Error history clear
Push key (execution key) assignment
How to enter the Check mode
1. Rotating the rotary switch, adjust the display (7 Seg LED) to “6” (third place).
After 2 or 3 seconds, the display will change to the execution mode.
2. The display mode number can be changed by pressing the
1
and
2
keys.
(See “Example” in step 2 in the Normal mode on page 22 and 23)
3. Press
5
and
6
keys to read the error history and error code.
4. Press
qh
key to clear the error history.
MODE LED display
Default display mode
Key
Description
1
DISP –
2
DISP +
3
–
4
–
5
ERROR HISTORY –
6
ERROR H
7
–
8
–
Key
Description
9
–
0
–
qa
–
qs
–
qd
–
qf
–
qg
–
qh
ERROR HISTORY CLEAR
: Software version display
: DTMS display
Error history display
Error code display (See “Error codes list” on page 19.)
L1
L2
L3
L4
L5
L6
L7
L8
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Display mode No.
Description
B
DIAG