– 16 –
AM Auto Scan/Stop Level Adjustment
Setting :
SOURCE
n
MODE button : AM
AM SENS Adjustment
Setting :
SOURCE
n
MODE button : AM
Procedure :
Adjust for a maximum reading on level meter.
T6, T7
530 kHz
Adjustment Location : See page 17.
Procedure :
1. Adjust RV4 on TU1 so that the reading on the digital voltmeter
changes point from minimum to maximum. (approx. 0.6 V)
2. Confirm that the set stops auto-scanning with AM RF signal
generator output level set at 33
±
4 dB.
Adjustment Location : See page 17.
Carrier frequency : 1000 kHz
30% amplitude
modulation by
400 Hz signal
output level : 30 dB (31.6
µ
V)
AM RF signal
generator
set
LINE OUT REAR
30
Ω
10 k
Ω
dummy
antenna
antenna
terminal
level
meter
15 pF
60 pF
+
–
AM RF signal
generator
set
LINE OUT REAR
30
Ω
10 k
Ω
dummy
antenna
antenna
terminal
level
meter
15 pF
60 pF
+
–
digital
voltmeter
AM VT OUT
+
–