Sony CCU-TX50 Скачать руководство пользователя страница 2

2

To prevent fire or shock hazard, do not expose 
the unit to rain or moisture.

To avoid electrical shock, do not open the 
cabinet. Refer servicing to qualified personnel 
only.

THIS APPARATUS MUST BE EARTHED.

This symbol is intended to alert the user to 
the presence of important operating and 
maintenance (servicing) instructions in the 
literature accompanying the appliance.

For the customers in the USA (for 
CCU-TX50)

This equipment has been tested and found to comply 
with the limits for a Class A digital device, pursuant to 
Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful 
interference when the equipment is operated in a 
commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instruction 
manual, may cause harmful interference to radio 
communications. Operation of this equipment in a 
residential area is likely to cause harmful interference in 
which case the user will be required to correct the 
interference at his own expense.

You are cautioned that any changes or modifications not 
expressly approved in this manual could void your 
authority to operate this equipment.

The shielded interface cable recommended in this 
manual must be used with this equipment in order to 
comply with the limits for a digital device pursuant to 
Subpart B of Part 15 of FCC Rules.

WARNING:

THIS WARNING IS APPLICABLE FOR 
USA ONLY.

Using this unit at a voltage other than 120V may require 
the use of a different line cord or attachment plug, or 
both. To reduce the risk of fire or electric shock, refer 
servicing to qualified service personnel.

For the customers in Europe (for 
CCU-TX50P)

This product with the CE marking complies with both 
the EMC Directive (89/336/EEC) and the Low Voltage 
Directive (73/23/EEC) issued by the Commission of the 
European Community.

Compliance with these directives implies conformity to 
the following European standards:
• EN60950: Product Safety
• EN55103-1: Electromagnetic Interference (Emission)
• EN55103-2: Electromagnetic Susceptibility 

(Immunity)

This product is intended for use in the following 
Electromagnetic Environment (s):
E1 (residential), E2 (commercial and light industrial), 
E3 (urban outdoors) and E4 (controlled EMC 
environment, ex. TV studio).

WARNING

Содержание CCU-TX50

Страница 1: ...3 863 129 11 1 Camera Control Unit 2004 Sony Corporation CCU TX50 50P Operating Instructions Before operating the unit please read this manual thoroughly and retain it for future reference ...

Страница 2: ...ence at his own expense You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules WARNING THIS WARNING IS APPLICABLE FOR USA ...

Страница 3: ...cs Mode 13 Settings of the Camera 13 Status Display of the Unit 13 Self diagnostics of the Camera System 14 Results of the Self diagnosis of the Internal Boards of the Unit 14 Diagnostics Page of the Camera 16 Exiting the Self diagnostic Mode 16 When an Error Occurs 16 Notes on Use 17 Specifications 17 General 17 Input signals 17 Output signals 17 Camera input output signals 18 Supplied accessorie...

Страница 4: ...n the front panel of the unit enables video camera operations to be controlled from the unit When the RCP D50 remote control panel is connected to the rear panel of the unit the video camera operation can be controlled from both the remote control panel and the front panel of the unit Wide array of input output signals The input and output connectors provided for the CCU TX50 50P include those for...

Страница 5: ...AM indicators light when the POWER switch is turned on The CAM indicator goes off when the power is turned off by the CAM PW button on the remote control panel Note If the fan in the CCU TX50 50P stops the MAIN indicator will flash simultaneously to warn you of the abnormal condition If this occurs turn the POWER switch off immediately and contact Sony service personnel c CABLE ALARM indicators OP...

Страница 6: ...amera The unit can control the camera when this button is lit g BARS button Press this button which lights up when pressed to send the color bar signal to the monitor The color bars then appear on the monitor h 5600K button Press this button which lights up when pressed to convert the color temperature electronically instead of using the optical filter i AUTO KNEE button Press this button which li...

Страница 7: ...normal shutter function UP DOWN selector When the CLS button lights The clear scan frequency is increased each time you press this selector to the UP position The clear scan frequency is reduced each time you press this selector to the DOWN position When the ON button lights The shutter speed is increased each time this selector to the UP position The shutter speed is reduced each time you press t...

Страница 8: ...me when the switch is set to this position BLACK Adjusts the black balance automatically one time when the switch is set to this position E ATW auto tracing white balance button Press this button which lights up when pressed to have the white balance adjusted automatically when lighting conditions change r MASTER BLACK adjustment knob Adjusts the master black levels of the R G and B signals simult...

Страница 9: ... cable will cause electric shock b AUDIO OUTPUT connectors XLR 3 pin Supply audio signals from the video camera c INPUT connectors The two connectors of each pair are loop through connectors When the upper connector is used and no connection is made to the lower connector the upper connector is terminated automatically with an impedance of 75 ohms a CAMERA connector b AUDIO OUTPUT connectors c INP...

Страница 10: ...signals to be output For details on the internal boards consult your nearest Sony dealer C PIX picture monitor output connector BNC type Supplies a video signal or video and character signals together to a picture monitor When using the RCP D50 Remote Control Panel you can select the signal output from the PIX connector using the MONITOR SELECT button on the menu of the RCP D50 When the signal out...

Страница 11: ...n and Location of Parts and Controls 11 i AC IN AC power input connector Connects to an AC power source using the supplied AC power cord Secure the power cord to the CCU TX50 50P using the supplied plug holder ...

Страница 12: ...on connections Triaxial cable The triaxial cable should never be connected to or disconnected from the CCU TX50 50P when the power is turned on Always turn the unit off first Video camera Some switches or controls on the video camera may not work when the camera is connected to the CCU TX50 50P For details refer to Operation Manuals of the video camera and the camera adaptor CA TX50 DXC D50 To an ...

Страница 13: ...display changes Settings of the Camera The settings and operations status of the camera are displayed 1 Master gain 2 4 3 is displayed when the images recorded in 16 9 format are output after converted to the images of the 4 3 mode 3 EVS is displayed when EVS of the electrical shutter is on 4 Shows the shutter speed currently selected 5 Shows the on off setting of the shutter 6 Shows the type of N...

Страница 14: ...p indication in the circuit The cable length may not be displayed correctly Fan power Fan status in the CCU power block Timer Power up time to devices connected CCU Power Status of the CCU power supply Page 2 CAMERA cable Camera cable connection status connected shorted CAMERA Data Camera data transmission status CAMERA Power Status of the power supply to a camera CAMERA Tone Camera ID tone status...

Страница 15: ...om Demodulating status of the intercom line CHU Data Data reception status from the camera Power Power supply status of the TR board AT board Reference Operation mode of the phase adjustment Gen Lock Locking status BATT Volt Voltage of the coin battery supplied with the AT board CCU Mode Operation mode of the CCU PLD Config Configuration result status of the PLD mounted on the AT board CCU Power C...

Страница 16: ...S SDI Composite Out 2 Signal type from composite output connector 2 VBS SDI Composite Out 3 Signal type from composite output connector 3 VBS SDI Composite Setup Setup settings to be added to the VBS signal Rear VDA Power supply status of the VDA board on the rear PLD Cofig Configuration completion status of the PLD mounted on the EN board Power Power supply status of the EN board Diagnostics Page...

Страница 17: ...neutral detergent then wipe dry Do not use volatile solvents such as alcohol or thinners as these may damage the finish Specifications General Power consumption 100 240 V AC 50 60 Hz maximum 1 3 A Peak inrush current 1 Power ON current probe method 50 A 240V 2 Hot switching inrush current measured in accordance with European standard EN55103 1 10 A 230V Cable length Maximum 750 m φ 8 5 mm Operatin...

Страница 18: ...e 1 75 ohms REMOTE 10 pin multi connector INTERCOM TALLY PGM D sub 25 pin 1 4W RTS TALLY 24 V DC TTL level or contact selectable MIC REMOTE D sub 15 pin 1 INCOM on the front panel XLR 5 pin 1 Supplied accessories AC power cord 1 AC power plug holder 1 Number plate 1 set Operating Instructions 1 CD ROM including multi lingual operating instructions 1 Warranty booklet 1 Optional accessories Remote C...

Страница 19: ...Sony Corporation ...