5-47
3-3.
SERVO SYSTEM ADJUSTMENTS
1. CAP FG Offset Adjustment (VC-215 board)
Improve the capstan servo characteristic. If it is not correct. jitters
will increase.
Mode
Camera recording (SP mode)
Subject
Arbitrary
Measurement Point
Pin
!™
of CN910 (CAP FG)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
69
Specified value
Duty = 50±0.5%
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 01, and set data: 81, and press the PAUSE
button of the adjustment remote commander. (to start up
automatic CAP FG offset adjustment.)
3) Select page: 2, address: 02, and check that the data is “01”.
4) Check that Duty of CAP FG signal satisfies the specified value.
If not, select page: 2, address: 01, set data: 00, and press the
PAUSE button, and then, repeat steps 2) to 4).
5) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjustment remote commander.
6) Select page: 0, address: 01, and set data: 00.
2. RF Switching Position Adjustment (VC-215 Board)
If deviated in this case causes switching noise or jitter on the played
back screen.
Mode
Playback
Signal
Alignment tape:
For tracking adjustment
WR5-1CP
Measurement Point
CH1: Pin
!¡
of CN910 (RF SWP)
CH2: Pin
6
of CN910 (PB RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
7C (upper digits), 7D (lower digits)
Specified Value
t1 = 0±10µsec
Adjusting Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 2A, and set data: 20, and press the PAUSE
button of the adjustment remote commander.
3) Select page: F, address: 7C, change the data and minimize “t1”,
and then press the PAUSE button of the adjustment remote
commander. (Coarse adjustment)
4) Select page: F, address: 7D, change the data and adjust so that
the switching position (t1) becomes the specified value. (Fine
adjustment)
5) Press the PAUSE button of the adjustment remote commander.
6) Select page: F, address: 2A, and set data: 00, and press the PAUSE
button of the adjustment remote commander.
7) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-5.
Fig. 5-3-6.
Содержание CCD-TRV26E
Страница 12: ...1 2 ...
Страница 13: ...1 3 ...
Страница 14: ...1 4 ...
Страница 15: ...1 5 ...
Страница 16: ...1 6 ...
Страница 17: ...1 7 ...
Страница 18: ...1 8 ...
Страница 19: ...1 9 ...
Страница 20: ...1 10 ...
Страница 21: ...1 11 ...
Страница 22: ...1 12 ...
Страница 23: ...1 13 ...
Страница 24: ...1 14 ...
Страница 25: ...1 15 ...
Страница 26: ...1 16 ...
Страница 27: ...1 17 ...
Страница 28: ...1 18 ...
Страница 29: ...1 19 ...
Страница 30: ...1 20 ...
Страница 31: ...1 21 ...
Страница 32: ...1 22 ...
Страница 33: ...1 23 ...
Страница 34: ...1 24 ...
Страница 35: ...1 25E ...