8. Standard8 REC Y Current Adjustment (VC-215 board)
CCD-TR315/TR416/TR416PK
CCD-TRV16/TRV16PK
Adjust the Y FM signal recording current.
Mode
VTR recording (SP mode)
Signal
No signal
Measurement Point
Pin
!º
of CN910 (REC RF)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
Adjustment Page
F
Adjustment Address
53 to 5A
Specified Value
A = 170±5mV
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “3. Bit value discrimination”
of “3-1-8. Service mode”).
3) Select page: D, address: 15, after memorizing the data , set the
bit value of bit7 to “0”.
4) Set to recording mode. (Use the wireless remote commander
of 8mm VCR, or connect Pin
6
of CN935 of DD-117 board
and GND with 4.7k
Ω
registor for a second.)
4.7k
Ω
registor : 1-249-425-11
5) Insert a tape, set to recording mode.
6)
Select page: 0, address: 01, and set data: 01.
7)
Select page: F, address: 5C, after note down the data , set data:
FF, and press the PAUSE button of the adjusting remote
commander.
8)
Select page: F, address: 65, after note down the data , set data:
00, and press the PAUSE button of the adjusting remote
commander.
9)
Select page: 3, address: 01, set data: 41, and press the PAUSE
button of the adjusting remote commander.
10) Select page: F, address: 54, change the data and set the Y signal
level (A) to the specified value.
11) Press the PAUSE button of the adjusting remote commander.
12) Select page: F, address: 54, and read the data (D
54
).
13) Calculate the adjustment data (hexadecimal) from the follow-
ing equations (hexadecimal calculation), and input each adjust-
ment address. (Refer to Table 5-1-2. Hexadecimal-Decimal
conversion Table.)
Address: 53
D
53
= D
54
Address: 55
D
55
= D
54
Address: 56
D
56
= D
54
Note:
After setting each data, be sure to press the PAUSE button
of the adjusting remote commander.
14) Write the following data in page: F, address: 57 to 5A.
Address
Data
57
80
58
80
59
80
5A
80
Note:
After setting each data, be sure to press the PAUSE button
of the adjusting remote commander.
15) Select page: F, address: 5C, set the data noted down at step 3),
press the PAUSE button of the adjusting remote commander.
16) Select page: F, address: 65, set the data noted down at step 4),
press the PAUSE button of the adjusting remote commander.
17) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
18) Select page: 0, address: 01, and set data: 00.
19) Select page: 0, address: 01, and set data: 01.
20) Select page: D, address: 14, and set the data memorized.
21) Press the PAUSE button of the adjusting remote commander.
22) Select page: D, address: 15, and set the data memorized.
23) Press the PAUSE button of the adjusting remote commander.
24) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-13.
Содержание CCD TRV16 - Hi8 Handycam Camcorder
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 39: ......
Страница 47: ...T901 T902 ...
Страница 48: ...20 20 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V 3 1V ...
Страница 49: ... TR MODEL COLOR EVF MODEL B W EVF MODEL ...
Страница 50: ......
Страница 55: ......
Страница 56: ......
Страница 57: ...REC PB ...
Страница 58: ......
Страница 59: ......
Страница 60: ...51 52 ...
Страница 61: ...55 53 54 56 ...
Страница 63: ...63 62 ...
Страница 67: ......
Страница 70: ......
Страница 74: ......
Страница 75: ......
Страница 77: ...3Vp p 7 2Vp p 7 5Vp p 7 6Vp p 3Vp p 3Vp p 3Vp p 3 4Vp p 2 7Vp p ...
Страница 78: ......
Страница 81: ...7 7 7 9 7 9 1 9 3 1 7 8 3 1 ...