BVP-E30/E30P M-V1
5-11 (E)
TP501
TP502
TP503
TP1
E501
E1
11
10
9
8
7
6
5
4
3
2
1
M
L
K
J
H
G
F
E
D
C
B
A
DPR-261 board (A side)
TP800
E2
5-4-2. Video Level Adjustment (2)
Equipment : Oscilloscope
Preparations
.
Turn the power off, and then disconnect the CCU
connected to the camera, and connect the AC-550/
550CE to the camera.
.
Remove the left side panel. (Refer to Section 1-5.)
.
OUTPUT/DCC switch (on the side panel)
→
BARS/OFF
.
Menu setting
MENU : SERVICE
PAGE :
DPR TRINNING
Adjustment Procedures
1.
Y Level Adjustment
Test Point :
TP502 (GND : E501) /DPR-261
Adjustment Point
.
ITEM :
Y LEVEL
Specifications : NTSC : A = 714
±
2 mV
PAL :
A = 700
±
2 mV
A
A
(NTSC)
(PAL)
(Oscilloscope)
(Oscilloscope)
2.
R-Y level Adjustment
Test Point :
TP503 (GND : E501) /DPR-261
Adjustment Point
.
ITEM :
R-Y LEVEL
Specifications : NTSC : A = 700
±
2 mV
PAL :
A = 525
±
2 mV
A
(NTSC)
(PAL)
A
(Oscilloscope)
(Oscilloscope)