9
Chapter 1 Overview
Pin number
1
Set input signal channel 1 (numeric keypad
function)
2
Set input signal channel 2 (numeric keypad
function)
3
Select sync signal (SYNC button function)
4
Set the screen to monochrome, or set for
automatic switching based on the input signal
(MONO MODE button function)
5
Safe area on/off (SAFE AREA button
function)
6, 7
Not connected
8
Tally lamp on/off
9
Ground
Function
All pin function assignments can be changed with the
REMOTE menu.
For information about the REMOTE menu, see “
[C2]
Assigning the Remote Control Functions (SET UP 2) —
REMOTE Menu” on page 34.
To switch each function between on and off or
between enable and disable, change pin connections in
the following way.
ON or enabled: Short each pin and pin 9 together.
OFF or disabled: Leave each pin open.
8
ISR (Interactive Status Reporting) connector
(female, D-sub 9-pin)
Connect to the ISR system.
9
CONTROL UNIT connector (female, D-sub 9-
pin)
Connects the BKM-10R Monitor Control Unit using a
cable with D-sub 9-pin plugs such as an RCC-5G/10G/
30G (not supplied) or the cable supplied with the
BKM-34H Monitor Control Unit Attachment Kit.
7
REMOTE 2 connector (female, D-sub 9-pin)
Forms a parallel switch and controls the monitor
externally. The pin assignment and factory setting