Sony BVE-700 Скачать руководство пользователя страница 5

1-1 (E)

BVE-700

1-1. Operating Environment

Operating guaranteed temperature :

+

d

C to 

+

35 

d

C

Performnace guaranteed temperature :

+

10 

d

C to 

+

30 

d

C

Operating humidity :

10 % to 90 %
(relative humidity)

Storage temperature :

_

20 

d

C to 

+

60 

d

C

Mass :

10 kg

Prohibited locations

.

Areas where the unit will be exposed to direct sunlight or
any other strong lights.

.

Dusty areas

.

Areas where it is subject to vibration.

.

Areas with strong electric or magnetic fields.

.

Areas near heat sources.

.

Areas where is subjected to electricity noise.

.

Areas where is subjected to static electricity noise.

Ventilation

The inside of the BVE-700 is cooled by a fan (rear and
sides).
The power supply can be damaged if the exhaust vent (rear
panel) and air intake (front panel) are blocked or the fan is
stopped.
Therefore, leave a blank space of more than 10 cm in the
front and back of the BVE-700.

1-2. Power Supply

1. Power specifications

A switching regulator is used for the power supply of this
unit.  The voltage within the range of 100 V to 240 V can
be used without changing the supply voltage.

Power requirements : AC 100 to 240 V 

±

 10 %

50/60 Hz

Current consumption : Maximum 2.5 A

(with all optional boards installed)

n

As the inrush current at turn-on is the maximum 25 A (at
100 V/50 A (at 200 V), the capacity of the AC power must
be commensurate in it.
If the capacity of the AC power is not the adequately large,
the breaker of the AC power at the supply side will operate
or the unit will abnormally operate.

Installation

2. Recommended Power Cord

w
.

The power cord is not supplied with the BVE-700. Be
sure to use the power cord that is applicable to places in

the area.
To avoid a fire or an electric shock, be sure to use the

designated power cord.

.

Do not damage the power cord.

Otherwise, a fire or electric shock may result.

Required Parts for the U.S.A. and Canada

1

 Power cord : 

!

1-551-812-11

Required Parts for Europe

1

 Power cord : 

!

1-782-929-21

1

AC inlet

1

AC inlet

Содержание BVE-700

Страница 1: ...EDITING CONTROL UNIT BVE 700 INSTALLATION MANUAL 1st Edition Serial No 10001 and Higher ...

Страница 2: ...ie ou de blessure n effectuer que les réparations indiquées dans le mode d emploi à moins d être qualifié pour en effectuer d autres Pour toute réparation faire appel à une personne compétente uniquement Attention when the product is installed in Rack 1 Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack please ...

Страница 3: ...ks 2 E Installation 1 1 Operating Environment 1 1 E 1 2 Power Supply 1 1 E 1 3 Installation Space 1 2 E 1 4 Matching Connectors and Cables 1 4 E 1 5 Input Output Signals of Connectors 1 5 E 1 6 Switch Settings on Boards and LED Description 1 8 E 1 7 Rack Mounting 1 11 E 1 8 Installing the BKE 701 1 12 E ...

Страница 4: ... This manual describes the overview system connection examples and specifica tions of the unit BKE 701 Installation Manual Supplied with BKE 701 This manual describes the information related to the installation of the unit BVE 700 BKE 701 Maintenance Manual Available on request This manual describes the information that premise the service of BVE 700 BKE 701 based on components replaced Trademarks...

Страница 5: ... Supply 1 Power specifications A switching regulator is used for the power supply of this unit The voltage within the range of 100 V to 240 V can be used without changing the supply voltage Power requirements AC 100 to 240 V 10 50 60 Hz Current consumption Maximum 2 5 A with all optional boards installed n As the inrush current at turn on is the maximum 25 A at 100 V 50 A at 200 V the capacity of ...

Страница 6: ...1 2 E BVE 700 1 3 Installation Space Processor unit 26 5 520 440 465 57 2 375 482 61 380 17 5 132 4 Unit mm 1 3 Installation Space ...

Страница 7: ...1 3 E BVE 700 Control panel unit Unit mm 340 315 5 281 277 2 315 16 9 15 1 3 Installation Space ...

Страница 8: ...Junction Shell 15 pin 1 563 376 11 Processor unit SDI INPUT BNC 75 Z BNC 75 Z SDI OUTPUT 5C FB coaxial cable 3 Processor unit REF VIDEO BNC 75 Z BNC 75 Z 5C 2V coaxial cable 4 Processor unit Control panel unit PANEL D sub 25 pin Female D sub 25 pin Male Connector 25 pin Male 1 560 904 11 1 Junction Shell 25 pin 1 563 377 11 Processor unit NETWORK RJ 45 modular jack 2 _ _ 1 To use plugs the followi...

Страница 9: ...n 1 _ No Connection 2 RXD Received data 3 TXD Transmitted data 4 _ No Connection 5 GND Ground 6 _ No Connection 7 RTS Not used at present 8 CTS Not used at present 9 _ No Connection _ EXT VIEW _ 1 5 6 9 _ EXT VIEW _ 5 1 9 6 GPI D sub 15 pin Female Pin No Signal Function 1 GND Ground 2 OUT 1A Relay output 1A 3 OUT 2A Relay output 2A 4 OUT 3 TTL Open collector output 3 5 OUT 4 TTL Open collector out...

Страница 10: ...2 V Panel Power Supply 16 RX_ Received data _ 17 GND Ground 18 TX Transmitted data 19 12 V Panel Power Supply 20 GND Ground 21 _ No Connection 22 GND Ground 23 12 V Panel Power Supply 24 12 V Panel Power Supply 25 GND Ground NETWORK 10BASE T 100BASE TX 8 pin Modular jack Pin No Signal Function 1 TX Transmitted data 2 TX_ Transmitted data _ 3 RX Received data 4 _ No Connection 5 _ No Connection 6 R...

Страница 11: ...l Power Supply 8 _ No Connection 9 GND Ground 10 GND Ground 11 GND Ground 12 GND Ground 13 GND Ground 14 12 V Panel Power Supply 15 12 V Panel Power Supply 16 TX_ Transmitted data _ 17 GND Ground 18 RX Received data 19 12 V Panel Power Supply 20 GND Ground 21 _ No Connection 22 GND Ground 23 12 V Panel Power Supply 24 12 V Panel Power Supply 25 GND Ground 1 13 14 25 EXT VIEW 1 5 Input Output Signa...

Страница 12: ...ights up D102 A 1 Orange _5 V AOK Lights up when _5 V power for analog is supplied Lights up D104 A 2 Green REF OK Lights up during reference signal input Lights up D105 A 2 Green PLL OK Lights up when the internal PLL circuit is locked to Lights up reference signal input during HD only Lights up dim when PLL is not locked during HD only Side A component side D105 D104 D102 D101 S651 A B C D E F G...

Страница 13: ...l that is input to REF IN Reference S2 Signal 1 2 3 4 5 1125 59 94 OFF OFF OFF OFF OFF 525 59 94 OFF OFF OFF ON OFF 1125 50 OFF ON ON OFF OFF 625 50 OFF ON ON ON OFF 1125 24 PsF ON OFF ON OFF ON 1125 23 98 PsF ON OFF OFF OFF ON OFF OPEN ON CLOSE Push the switch to the UP position Any switch setup other than the those shown on the above table is invalid S2 6 Factory use S2 7 Setup status OPEN Norma...

Страница 14: ...onnection when network is not connected D12 L 4 Green RUN Factory use Undefined D13 L 4 Red FAIL Factory use Lights off D14 K 4 Orange VD Lights up when VIDEO reference Lights up Flickers a bit signal is supplied to the CPU board Flickers a bit D15 A 5 Orange 5V Lights up when 5 V power for Lights up digital is supplied D16 A 5 Orange 3V Lights up when 3 V power for Lights up digital is supplied D...

Страница 15: ...crews on the rack angle and fix the unit in the rack If the screws on the rack angle are not tightened the unit may slip from the rack and fall causing injury c When mounting the unit in the rack note the following Be sure to mount in the rack with two persons or more Be careful not to catch your fingers or hands in the rack mount rail or others Mount in the rack in a stable position n If several ...

Страница 16: ...of the equipment with the rail and slide the equipment to the rear n The rack tools are hooked on the rails as shown below 6 Turn off the main power of this unit and disconnect the plug from the outlet 7 Fully loosen the four screws with drop safe and remove the front panel 8 Fix the rack angle in the rack using the specified screws 9 Attach the front panel to the equipment 1 8 Installing the BKE ...

Страница 17: ...de Sony Corporation Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdrücklich d...

Страница 18: ...Printed in Japan Sony Corporation 2000 8 16 Communication System Solutions Network Company 2000 BVE 700 SY J E 3 205 021 01 ...

Отзывы: