SONY KLV-40U100M
28
6. White Balance, Luminance Adjustment
Approximately 30 minutes should be allowed for warm up the unit before proceeding white balance adjustment.
1. Preparation
Connect power cable for Chroma-C210 and K8256, then start industrial PC;
Connect Chroma-C210 and 480i signal source to PC in their Power off status;
Connect one terminal of 480i signal cable to the signal source, the other one should be in suitable condition;
Power on all signal sources;
Focus the camera lens on 0-cal (closed) while turn on Chroma-C210, press 0-CAL for calibrating
(
00 channel
)
,
after the panel digits of Chroma-C210 flash, focus the camera lens on MEAS; meanwhile, the lens close to TV.
2. Operation Steps:
a. Connect the signal cables to the corresponding input jack.
b. Color temperature adjustment:
1) Press “MENU” button to enter OSD, and complete the following processes:
Power saving: OFF
Select picture vivid;
Activate picture reset function;
2) adjust White Balance for cool temperature;
Select Cool color temperature in the OSD menu, and press OK-OK-MUTE-OK-MUTE-MENU to enter into
factory mode;
Exchange Timing 78, pattern 45 (480i, 65% white) for K-8256, fix GG=240, decrease RG, BG (if G<240,
B=255), X=0.2728+/-0.002
,
Y= 0.2660+/-0.002 (RG, GG, BG<=255).
Exchange TIMING78
,
PATTERN46
(
480i,30%WHITE
)
for K-8256, if GO or BO or RO=125, adjust the other
three factors to make X=0.2728+/-0.003
,
Y=0.2660+/-0.003 (RO, GO, BO<=125)
Repeat the above two steps to meet X
=
0.2728
+
/-0.002
,
Y
=
0.2660+/-0.002 at 65% white and X
=
0.2728
+
/-0.003
,
Y
=
0.2660+/-0.003 at 30% white.
3) adjust White Balance for neutral temperature;
Select neutral color temperature in the OSD menu, and press OK-OK-MUTE-OK-MUTE-MENU to enter into
factory mode;
Exchange Timing 78, pattern 45 (480i, 65% white) for K-8256, if GG or BG or RG
≥
253, adjust the other three
factors to make X=0.2900+/-0.002
,
Y= 0.2920+/-0.002 (RG, GG, BG<=255).
Exchange TIMING78
,
PATTERN46
(
30%WHITE
)
for K-8256, if GO or BO or RO=125, adjust the other three
factors to make X=0.2900+/-0.003
,
Y=0.2940+/-0.003(RO,GO,BO<=125)
Repeat the above two steps to meet X
=
0.2900
+
/-0.002
,
Y
=
0.2920+/-0.002 at 65% white and X
=
0.2900
+
/-0.003
,
Y
=
0.2940+/-0.003at 30% white.
4) adjust White Balance for warm temperature;
Select warm color temperature in the OSD menu, and press OK-OK-MUTE-OK-MUTE-MENU to enter into
factory mode;
Exchange Timing 78, pattern 45 (480i, 65% white) for K-8256, if GG or BG or RG
≥
253, adjust the other three
factors to make X=0.3190+/-0.002, Y=0.3250+/-0.002 (RG, GG, BG<=255).
Exchange TIMING78
,
PATTERN46 (30%WHITE) for K-8256, if GO or BO or RO=125, adjust the other three
factors to make X=0.3200+/-0.003, Y=0.3270+/-0.003(RO, GO, BO<=125)
Repeat the above two steps to meet X
=
0.3190
+
/-0.002
,
Y
=
0.3250+/-0.002 at 60% white and X
=
0.3200
+
/-0.003 Y
=
0.3270+/-0.003 at 30% white.
Содержание BRAVIA KLV-40U100M
Страница 5: ...SONY KLV 40U100M 4 2 Operations Instructions 2 1 Remote Control Description ...
Страница 7: ...SONY KLV 40U100M 6 1 Picture Setting ...
Страница 8: ...SONY KLV 40U100M 7 Picture Setting for PC Signal Input 2 Sound Setting ...
Страница 9: ...SONY KLV 40U100M 8 3 Screen Setting ...
Страница 10: ...SONY KLV 40U100M 9 ...
Страница 11: ...SONY KLV 40U100M 10 Screen Setting for PC Signal Input ...
Страница 12: ...SONY KLV 40U100M 11 4 Setup Setting ...
Страница 24: ...SONY KLV 40U100M 23 The end N A ...
Страница 54: ...SONY KLV 40U100M 53 8 PCB LAYOUT 8 1 Main Board ...
Страница 55: ...SONY KLV 40U100M 54 ...
Страница 56: ...SONY KLV 40U100M 55 8 2 Power Board ...
Страница 57: ...SONY KLV 40U100M 56 8 3 Key Board ...
Страница 58: ...SONY KLV 40U100M 57 9 Block Diagram 9 1 Main Board ...
Страница 59: ...SONY KLV 40U100M 58 ...
Страница 60: ...SONY KLV 40U100M 59 9 2 Power Board ...
Страница 61: ...SONY KLV 40U100M 60 10 Exploded View ...
Страница 72: ...SONY KLV 40U100M 71 11 3 Key Board ...
Страница 73: ...SONY KLV 40U100M 72 11 4 Earphone Board ...
Страница 74: ...SONY KLV 40U100M 73 12 Wiring Diagram ...