![Sony BRAVIA KDL-40X4500 Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/sony/bravia-kdl-40x4500/bravia-kdl-40x4500_service-manual_410626040.webp)
KDL-40/46/55XBR45 (AUS), 40/46/55X4500 (NZ, ES) 2-6
1) Power Error (R ED 2 tim es blink )
This indicates POWER Error, Low B error of 12V from G6 board. TV Micro (on AAS board)
monitors pin79 and pin138 to detect POWER_ERR and shuts down chassis power to
Standby status.
TV Micro pin138 Normal condition : Low / Error case : High
TV Micro pin79 i_lb_err< 0.7V(PW_ERR_LEV)
- Check 12V at CN 1000 on AAS board. And F1001 on AAS has 12V or not.
- Check G6 board.
2) T-CON Error (R ED 5 tim es blink )
This indicates T-CON RDY signal error from timing controller of Panel module.
BE micro pin128 on FBA board detects it.
BE Micro pin128 Normal condition : High / Error case : Low
Replace Panel module.
3) B ack Light Error (R ED 6 tim es blink )
This indicates panel power circuit error such as inverter.
BE micro pin 78 on FBA board detects it.
BE Micro pin 78 Normal condition : High / Error case : Low
Replace D4 board in case of GL board in case of LED model.