Service Adjustment
KDL- 22, 26 EX420, 32,40,46 EX520
RM-GD020, CD013
KDL- 22 EX423, 26 EX423, 32 EX420, 32, 40, 46 EX523
RM-GD020
In VPC service mode:
a. Select 000 DATA_COPY category by pressing key
2
or
5
on remote
commander.
C
f
0
1
3
6
4-7. Restore WB / Gamma adj-data to B board.
4-8. Change the emitter output level (Applicable only for TD model).
1. Purpose to reduce the emitter LED output power strength.
2. Select VPC service mode and then press:
a. Select 005 TD category by pressing key
2
or
5
on remote commander.
b Select 000 EMIT STR item by pressing key
1
or
4
on remote commander
b. Change data from
0
to
1
by pressing key
3
or
6
on remote commander.
c. Wait until data is changed from
1
to
3
.
d. When data is changed from
1
to
3
, restoring process is finished.
e. In case data is changed from
1
to
2
, keep default setting.
(No more process is needed.)
b. Select 000 EMIT_STR item by pressing key
1
or
4
on remote commander.
c. Change data from
0
to
1
by pressing key
3
or
6
on remote commander.
0: Strong (Default)
1: Weak
d. Save by pressing
Mute
&
0
or
10
& Reboot.
VPC SERVICE
000
DATA COPY
VPC SERVICE
000
DATA COPY
VPC SERVICE
000 DATA_COPY
000 BU_TRANS 3
DATA TRANSFER SUCCESS
000 DATA_COPY
000 BU_TRANS 1
DO NOT POWER OFF
DO NOT TOUCH ANY KEY NOW
b
a
b
c
005 TD
000 EMIT_STR 1
Sub Service menu
End restore process menu
sample
DATA TRANSFER SUCCESS
Restore process menu sample
DO NOT TOUCH ANY KEY NOW
a
b
c
Remote Commander
N t
d
Notes:
1. This restoration should be applied after USB-DL being assembled when
B Board is replaced.
2. This process only applicable for 120Hz / 240Hz models only.
Remote Commander
51