WARNING

To prevent fire or shock hazard, do not expose the unit to
rain or moisture.
To avoid electrical shock, do not open the cabinet.  Refer
servicing to qualified personnel only.

VORSICHT

Um Feuergefahr und die Gefahr eines elektrischen Schlages
zu vermeiden, darf das Gerät weder Regen noch
Feuchtigkeit ausgesetzt werden.
Um einen elektrischen Schlag zu vermeiden, darf das
Gehäuse nicht geöffnet werden.  Überlassen Sie
Wartungsarbeiten stets nur qualifiziertem Fachpersonal.

For the customers in the USA
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules.  These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment.  This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications.  Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
You are cautioned that any changes or modifications not
expressly approved in this manual could void your authority
to operate this equipment.
The shielded interface cable recommended in this manual
must be used with this equipment in order to comply with the
limits for a digital device pursuant to Subpart B of Part 15 of
FCC Rules.

WARNING:  THIS WARNING IS APPLICABLE FOR USA
ONLY.
If used in USA, use the UL LISTED power cord specified
below.
DO NOT USE ANY OTHER POWER CORD.

Plug Cap

Parallel blade with ground pin
(NEMA 5-15P Configuration)

Cord

Type SJT, three 16 or 18 AWG wires

Length

Less than 2.5 m (8 ft. 3 in.)

Rating

Minimum 10 A, 125 V

Using this unit at a voltage other than 120V may require the
use of a different line cord or attachment plug, or both.  To
reduce the risk of fire or electric shock, refer servicing to
qualified service personnel.

For the customers in Europe
This product with the CE marking complies with both the
EMC Directive (89/336/EEC) and the Low Voltage Directive
(73/23/EEC) issued by the Commission of the European
Community.
Compliance with these directives implies conformity to the
following European standards:
• EN60950: Product Safety
• EN55103-1: Electromagnetic Interference (Emission)
• EN55103-2: Electromagnetic Susceptibility (Immunity)
This product is intended for use in the following
Electromagnetic Environment(s):
E1 (residential), E2 (commercial and light industrial), E3
(urban outdoors) and E4 (controlled EMC environment, ex.
TV studio).

Pour les clients européens
Ce produit portant la marque CE est conforme à la fois à la
Directive sur la compatibilité électromagnétique (EMC) (89/
336/CEE) et à la Directive sur les basses tensions (73/23/
CEE)  émises par la Commission de la Communauté
Européenne.
La conformité à ces directives implique la conformité aux
normes européennes suivantes:
• EN60950: Sécurité des produits
• EN55103-1: Interférences électromagnétiques (émission)
• EN55103-2: Sensibilité électromagnétique (immunité)
Ce produit est prévu pour être utilisé dans les
environnements électromagnétiques suivants:
E1 (résidentiel), E2 (commercial et industrie légère),
E3 (urbain extérieur) et E4 (environnement EMC contrôlé ex.
studio de télévision).

Für Kunden in Europa
Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt
sowohl die EMV-Direktive (89/336/EEC) als auch die
Direktive Niederspannung (73/23/EEC) der EG-Kommission.
Die Erfüllung dieser Direktiven bedeutet Konformität für die
folgenden Europäischen Normen:
• EN60950: Produktsicherheit
• EN55103-1: Elektromagnetische Interferenz (Emission)
• EN55103-2: Elektromagnetische Empfindlichkeit
(Immunität)
Dieses Produkt ist für den Einsatz unter folgenden
elektromagnetischen Bedingungen ausgelegt:
E1 (Wohnbereich), E2 (kommerzieller und in beschränktem
Maße industrieller Bereich), E3 (Stadtbereich im Freien) und
E4 (kontrollierter EMV-Bereich, z.B. Fernsehstudio).

WARNING

This unit has no power switch.
When installing the unit, incorporate a readily accessible
disconnect device in the fixed wiring, or connect the power
cord to socket-outlet which must be provided near the unit
and easily accessible.
If a fault should occur during operation of the unit, operate
the disconnect device to switch the power supply off, or
disconnect the power cord.

WARNUNG

Dieses Gerät hat keinen Netzschalter.
Beim Einbau des Geräts ist daher im Festkabel ein leicht
zugänglicher Unterbrecher einzufügen, oder das Netzkabel
muß mit in der Nähe des Geräts befindlichen, leicht
zugänglichen Wandsteckdose verbunden werden.
Wenn während des Betriebs eine Funktionsstörung auftritt,
ist der Unterbrecher zu betätigen bzw. das Netzkabel
abzuziehen, damit die Stromversorgung zum Gerät
unterbrochen wird.

AVERTISSEMENT

Cet appareil n’a pas d’interrupteur d’alimentation.
Quand vous installez l’appareil, branchez un interrupteur
d’alimentation facile d’accès sur le câble fixe ou raccordez le
cordon d’alimentation à une prise proche de l’appareil et
facile d’accès.
En cas de problème en cours d’utilisation, déconnectez
l’appareil par l’interrupteur d’alimentation ou débranchez le
cordon d’alimentation.

WARNING
THIS APPARATUS MUST BE EARTHED.

WARNUNG
DIESES GERÄT MUSS GEERDET WERDEN.

AVERTISSEMENT
CET APPAREIL DOIT ÊTRE RELIÉ À LA TERRE.

Содержание BKS-R1618

Страница 1: ...OPERATION MANUAL English 1st Edition Revised 2 UNIVERSAL CONTROL UNIT BKS R3219 R1618 ...

Страница 2: ... urban outdoors and E4 controlled EMC environment ex TV studio Pour les clients européens Ce produit portant la marque CE est conforme à la fois à la Directive sur la compatibilité électromagnétique EMC 89 336 CEE et à la Directive sur les basses tensions 73 23 CEE émises par la Commission de la Communauté Européenne La conformité à ces directives implique la conformité aux normes européennes suiv...

Страница 3: ...e of Multiple Control Units 8 Route Function 8 Phantom Function 9 VTR Control 9 Monitor Function 10 Level Control 10 Four Destination Control 10 Locations and Functions of Parts 11 Preparations 13 Settings on the Control Terminal 13 Preparation for the BKS R3219 13 Settings by Using the Buttons Setup Function 15 Operations 17 Specifications 18 ...

Страница 4: ...d with a phantom name can be switched by pressing one button 1 Levels To handle different kinds of signals simultaneously it is necessary to use a routing switcher for each type of signal and these types are called levels For example a recording to be made on a VTR requires the use of five signal levels video audio 1 audio 2 time code and remote control signals The BKS R3219 R1618 Universal Contro...

Страница 5: ...nal or the setup function of this unit allows you to define the function of each button The settings are made for each button For details on making settings on the control terminal refer to the Installation Manual supplied with the routing switcher Expanding the number of sources and destinations You may expand the controllable number of sources and destinations using two or more control units as ...

Страница 6: ...ZR 2000 installed Primary station Level 1 Video Source VTR Destination VTR S BUS line Signal RS 232C T Bridge 75 ohm terminator3 Matrix level Video Video Audio Time code DVS A3232 Audio Routing Switcher S 2 Routing switcher HDS X3700 Video Routing Switcher P 1 DVS V3232M Video Routing Switcher S 2 DVS TC3232 Time Code Routing Switcher S 2 Secondary station Video Audio Time code Level 2 Level 3 Lev...

Страница 7: ...eo routing switcher Audio routing switcher Destination VTR Audio source Audio source Selected source bright green Source select buttons dim green LOCK CHOP MONI SOUR DEST LEVEL DESC TYPE D T DIRECT X Y CLEAR SHIFT ALL TAKE PROT TAKE PROT TAKE PROT TAKE PROT TAKE PROT TAKE PROT TAKE PROT TAKE PROT TAKE A B PAGE BKS R3216 SELECTOR PRESET 1 2 3 4 13 14 15 16 5 6 7 8 17 18 19 20 9 10 11 12 21 22 23 24...

Страница 8: ...spoint is switched on switcher A in the figure below normally IN5 appears as the source name If the route function has been set the source name selected on switcher A appears To activate the route function set the destination of switcher A destination and source of switcher B and level In the case of the figure below set OUT1 OUT2 IN5 10000000 When you use the route function switching is possible ...

Страница 9: ...d with the connector number of the destination selected when phantom switching For example if the destination is OUT005 the connector number of the destination is 015 and the offset value is 2 2 the destination 017 is switched To execute the destination offset local phantom first select and check the destination Examples of this Phantom are given below Example 1 Assign a source audio source AUD007...

Страница 10: ...ource with D1 MONI STATUS PROT LOCK CHOP BKS R3219 14 15 16 13 LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 MONI STATUS PROT LOCK CHOP BKS R1618 14 15 16 13 LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 MONI STATUS PROT LOCK CHOP BKS R3219 Block 1 Block 3 Block 4 Block 2 MONI STATUS PROT LOCK CHOP BKS R1618 Block 1 Block 3 Block 4 Block 2 BKS R3219 BKS R1618 BKS R3219 BKS R1618 Level Control You can assign levels to source ...

Страница 11: ...the destination or the source that the offset value is added is automatically selected For details on setting the monitor refer to the installation manual supplied with the routing switcher 3 PROT protect button lamp This button has two functions to set and release protection for the output connector destination and to indicate whether the currently selected destination is protected or not Protect...

Страница 12: ...s for blocks 1 to 4 are set to destination select buttons 1 to 4 For details on defining the button functions refer to the Installation Manual supplied with the routing switcher Source selection function lit in green When you press a button the signal fed to the switcher source corresponding to the pressed button is selected and is supplied to the output connector destination If the phantom functi...

Страница 13: ...Terminal Before switching signals with this unit the following preparations should be made on the control terminal connected to the primary station of the S BUS data link For details on making the settings refer to the Installation Manual supplied with the routing switcher 1 Set the type of the input and output connector name to either the type name and number mode or the description name mode 2 S...

Страница 14: ... on the source destination select buttons Then you can see at a glance what functions you have assigned to each button Making a key label 1 Copy the key label guide shown below onto a sheet of OHP paper Key label guide For a large button 14 14 mm For a small button 9 5 9 5 mm 2 Write the name on the copied paper 3 Cut the paper to the button size as shown below VTR 1 CAM 3 14 mm 14 mm 9 5 mm 9 5 m...

Страница 15: ...d below Initializing the settings While holding down buttons 1 and 2 turn the power on The following items are set to the factory set conditions 1 Status display mode 2 Single use mode 3 Phantom partial protect mode Note Press buttons until the lamp check on the panel is completed Setting single use mode While holding down buttons 5 and 8 turn the power on Use this mode when this unit is to be use...

Страница 16: ...uttons 9 and 11 turn the power on If one of the crosspoints set for a phantom is protected switching of all the crosspoints of the phantom is prohibited Setting to phantom partial protect mode While holding down buttons 9 10 and 11 turn the power on If one of the destinations set on a phantom is protected switching of the crosspoints including the protected destination is prohibited but the other ...

Страница 17: ...ed for the destination on the panel The source button selected for the destination is lit in bright green When there is no source button selected for the destination on the panel All the source buttons are lit in dim green Selecting when the unit is connected to the monitor S BUS data link When you wish to monitor the input and output signals of the DVS V3232M V6464M Video Routing Switcher with an...

Страница 18: ... V AC for the U S A and Canada 100 to 240 V AC for the other countries 50 60 Hz Current consumption BKS R3219 0 25 A BKS R1618 0 2 A Peak inrush current BKS R3219 1 Power ON current probe method 28 A 240 V 2 Hot switching inrush current measured in accordance with European standard EN55103 1 8 A 230 V Peak inrush current BKS R1618 1 Power ON current probe method 28 A 240 V 2 Hot switching inrush c...

Страница 19: ...des acquéreurs de l équipement décrit dans ce manuel Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind und ausschli...

Страница 20: ...BKS R3219 R1618 WW 3 203 874 23 1 2000 09 1999 Sony Corporation Communication System Solutions Network Company ...

Отзывы: