OPERATION MANUAL    

[English]

1st Edition (Revised 2)

UNIVERSAL CONTROL UNIT

BKS-R3219/R1618

Содержание BKS-R1618

Страница 1: ...OPERATION MANUAL English 1st Edition Revised 2 UNIVERSAL CONTROL UNIT BKS R3219 R1618 ...

Страница 2: ... urban outdoors and E4 controlled EMC environment ex TV studio Pour les clients européens Ce produit portant la marque CE est conforme à la fois à la Directive sur la compatibilité électromagnétique EMC 89 336 CEE et à la Directive sur les basses tensions 73 23 CEE émises par la Commission de la Communauté Européenne La conformité à ces directives implique la conformité aux normes européennes suiv...

Страница 3: ...e of Multiple Control Units 8 Route Function 8 Phantom Function 9 VTR Control 9 Monitor Function 10 Level Control 10 Four Destination Control 10 Locations and Functions of Parts 11 Preparations 13 Settings on the Control Terminal 13 Preparation for the BKS R3219 13 Settings by Using the Buttons Setup Function 15 Operations 17 Specifications 18 ...

Страница 4: ...d with a phantom name can be switched by pressing one button 1 Levels To handle different kinds of signals simultaneously it is necessary to use a routing switcher for each type of signal and these types are called levels For example a recording to be made on a VTR requires the use of five signal levels video audio 1 audio 2 time code and remote control signals The BKS R3219 R1618 Universal Contro...

Страница 5: ...nal or the setup function of this unit allows you to define the function of each button The settings are made for each button For details on making settings on the control terminal refer to the Installation Manual supplied with the routing switcher Expanding the number of sources and destinations You may expand the controllable number of sources and destinations using two or more control units as ...

Страница 6: ...ZR 2000 installed Primary station Level 1 Video Source VTR Destination VTR S BUS line Signal RS 232C T Bridge 75 ohm terminator3 Matrix level Video Video Audio Time code DVS A3232 Audio Routing Switcher S 2 Routing switcher HDS X3700 Video Routing Switcher P 1 DVS V3232M Video Routing Switcher S 2 DVS TC3232 Time Code Routing Switcher S 2 Secondary station Video Audio Time code Level 2 Level 3 Lev...

Страница 7: ...eo routing switcher Audio routing switcher Destination VTR Audio source Audio source Selected source bright green Source select buttons dim green LOCK CHOP MONI SOUR DEST LEVEL DESC TYPE D T DIRECT X Y CLEAR SHIFT ALL TAKE PROT TAKE PROT TAKE PROT TAKE PROT TAKE PROT TAKE PROT TAKE PROT TAKE PROT TAKE A B PAGE BKS R3216 SELECTOR PRESET 1 2 3 4 13 14 15 16 5 6 7 8 17 18 19 20 9 10 11 12 21 22 23 24...

Страница 8: ...spoint is switched on switcher A in the figure below normally IN5 appears as the source name If the route function has been set the source name selected on switcher A appears To activate the route function set the destination of switcher A destination and source of switcher B and level In the case of the figure below set OUT1 OUT2 IN5 10000000 When you use the route function switching is possible ...

Страница 9: ...d with the connector number of the destination selected when phantom switching For example if the destination is OUT005 the connector number of the destination is 015 and the offset value is 2 2 the destination 017 is switched To execute the destination offset local phantom first select and check the destination Examples of this Phantom are given below Example 1 Assign a source audio source AUD007...

Страница 10: ...ource with D1 MONI STATUS PROT LOCK CHOP BKS R3219 14 15 16 13 LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 MONI STATUS PROT LOCK CHOP BKS R1618 14 15 16 13 LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 MONI STATUS PROT LOCK CHOP BKS R3219 Block 1 Block 3 Block 4 Block 2 MONI STATUS PROT LOCK CHOP BKS R1618 Block 1 Block 3 Block 4 Block 2 BKS R3219 BKS R1618 BKS R3219 BKS R1618 Level Control You can assign levels to source ...

Страница 11: ...the destination or the source that the offset value is added is automatically selected For details on setting the monitor refer to the installation manual supplied with the routing switcher 3 PROT protect button lamp This button has two functions to set and release protection for the output connector destination and to indicate whether the currently selected destination is protected or not Protect...

Страница 12: ...s for blocks 1 to 4 are set to destination select buttons 1 to 4 For details on defining the button functions refer to the Installation Manual supplied with the routing switcher Source selection function lit in green When you press a button the signal fed to the switcher source corresponding to the pressed button is selected and is supplied to the output connector destination If the phantom functi...

Страница 13: ...Terminal Before switching signals with this unit the following preparations should be made on the control terminal connected to the primary station of the S BUS data link For details on making the settings refer to the Installation Manual supplied with the routing switcher 1 Set the type of the input and output connector name to either the type name and number mode or the description name mode 2 S...

Страница 14: ... on the source destination select buttons Then you can see at a glance what functions you have assigned to each button Making a key label 1 Copy the key label guide shown below onto a sheet of OHP paper Key label guide For a large button 14 14 mm For a small button 9 5 9 5 mm 2 Write the name on the copied paper 3 Cut the paper to the button size as shown below VTR 1 CAM 3 14 mm 14 mm 9 5 mm 9 5 m...

Страница 15: ...d below Initializing the settings While holding down buttons 1 and 2 turn the power on The following items are set to the factory set conditions 1 Status display mode 2 Single use mode 3 Phantom partial protect mode Note Press buttons until the lamp check on the panel is completed Setting single use mode While holding down buttons 5 and 8 turn the power on Use this mode when this unit is to be use...

Страница 16: ...uttons 9 and 11 turn the power on If one of the crosspoints set for a phantom is protected switching of all the crosspoints of the phantom is prohibited Setting to phantom partial protect mode While holding down buttons 9 10 and 11 turn the power on If one of the destinations set on a phantom is protected switching of the crosspoints including the protected destination is prohibited but the other ...

Страница 17: ...ed for the destination on the panel The source button selected for the destination is lit in bright green When there is no source button selected for the destination on the panel All the source buttons are lit in dim green Selecting when the unit is connected to the monitor S BUS data link When you wish to monitor the input and output signals of the DVS V3232M V6464M Video Routing Switcher with an...

Страница 18: ... V AC for the U S A and Canada 100 to 240 V AC for the other countries 50 60 Hz Current consumption BKS R3219 0 25 A BKS R1618 0 2 A Peak inrush current BKS R3219 1 Power ON current probe method 28 A 240 V 2 Hot switching inrush current measured in accordance with European standard EN55103 1 8 A 230 V Peak inrush current BKS R1618 1 Power ON current probe method 28 A 240 V 2 Hot switching inrush c...

Страница 19: ...des acquéreurs de l équipement décrit dans ce manuel Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind und ausschli...

Страница 20: ...BKS R3219 R1618 WW 3 203 874 23 1 2000 09 1999 Sony Corporation Communication System Solutions Network Company ...