Outline

The BKM-14L Auto Set-Up Probe is a white balance adjustment
probe designed for use with BVM series monitors.  This probe
has the following features.
• The auto set-up function allows automatic white balance

adjustment.

• A color analysis function that indicates chromaticity values (x

and y) and luminance (Y) makes color matching of monitors
convenient.

• Handy and easy to use.

Operation

Plug the probe connector into the OPTION connector on the front
of the monitor, and firmly press the probe head onto the monitor
screen so that it is held on the screen by the suction pad.

Use the monitor on-screen menu to operate the probe.  For details
on the operation, refer to the operation manual for the monitor
being used.

Notes on operation

• Do not touch the sensor and connector with your finger or a metal

object.

• Do not bend, drop or subject the probe to violent shocks.
• Avoid heat, moisture and direct sunlight.
• If the inner surface of the suction pad is contaminated, there is a

possibility it will not adhere to the screen.  Remove any
contamination from the pad before pressing the probe head onto
the monitor screen.

For the customers in Europe

This product with the CE marking complies with the EMC
Directive (89/336/EEC) issued by the Commission of the
European Community.
Compliance with this directive implies conformity to the
following European standards:
• EN55103-1: Electromagnetic Interference (Emission)
• EN55103-2: Electromagnetic Susceptibility (Immunity)
This product is intended for use in the following
Electromagnetic Environment(s):
E1 (residential), E2 (commercial and light industrial), E3
(urban outdoors) and E4 (controlled EMC environment, ex.
TV studio).

Pour les clients européens

Ce produit portant la marque CE est conforme à la Directive
sur la compatibilité électromagnétique (EMC) (89/336/CEE)
émise par la Commission de la Communauté européenne.
La conformité à cette directive implique la conformité aux
normes européennes suivantes:
• EN55103-1: Interférences électromagnétiques (émission)
• EN55103-2: Sensibilité électromagnétique (immunité)
Ce produit est prévu pour être utilisé dans les
environnements électromagnétiques suivants:
E1 (résidentiel), E2 (commercial et industrie légère), E3
(urbain extérieur) et E4 (environnement EMC contrôlé, ex.
studio de télévision).

Für Kunden in Europa

Dieses Produkt besitzt die CE-Kennzeichnung Und erfüllt
die EMV-Richtlinie (89/336/EWG) der EG-Kommission.
Angewandte Normen:
• EN55103-1: Elektromagnetische Verträglichkeit

(Störaussendung)

• EN55103-2: Elektromagnetische Verträglichkeit

(Störfestigkeit),

für die folgenden elektromagnetischen Umgebungen: E1
(Wohnbereich), E2 (kommerzieller und in beschränktem
Maße industrieller Bereich), E3 (Stadtbereich im Freien)
und E4 (kontrollierter EMV-Bereich, z.B. Fernsehstudio)

For the customers in the USA

This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules.  These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment.  This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications.  Operation of this
equipment in a residential area is likely to cause harmful
interference in which case the user will be required to
correct the interference at his own expense.

You are cautioned that any changes or modifications not
expressly approved in this manual could void your authority
to operate this equipment.

The shielded interface cable recommended in this manual
must be used with this equipment in order to comply with
the limits for a digital device pursuant to Subpart B of Part
15 of FCC Rules.

Monitor

Screen

Probe head

OPTION connector

Probe connector

Содержание BKM-14L

Страница 1: ...トセットアッププローブBKM 14Lは BVMシリーズモニ ター用のホワイトバランス調整プローブです 本機には 次のような特長があります オートセットアップ機能により ホワイトバランスの自動調 整が可能 色度座標 x y 輝度 Y を表示するカラーアナライズ機能 により モニターの色合わせに便利 ハンディタイプの使いやすいデザイン 取り扱い操作 本機のコネクターをモニター前面のOPTION端子に接続し 本 機を吸盤でモニタースクリーンに圧着します 本機を操作するには モニターのメニューを使います 操作に ついては 使用しているモニターのオペレーションマニュアル をご覧ください 取り扱い上のご注意 センサー部および端子部に手や金属で触れないでください 曲げたり落としたりして 衝撃を与えないでください 熱 水分 直射日光を避けてください 吸盤の圧着面が汚れていると スクリーンに付かないことが ...

Страница 2: ...ght industrial E3 urban outdoors and E4 controlled EMC environment ex TV studio Pour les clients européens Ce produit portant la marque CE est conforme à la Directive sur la compatibilité électromagnétique EMC 89 336 CEE émise par la Commission de la Communauté européenne La conformité à cette directive implique la conformité aux normes européennes suivantes EN55103 1 Interférences électromagnétiq...

Страница 3: ...re measured under the luminance of 40 cd m2 Repetition accuracy Y 1 x y 0 002 3 cd m2 Y 200 cd m2 x y 0 005 1 cd m2 Y 3 cd m2 Mass 135 g 4 oz Operating temperature 0 to 40 C 32 to 104 F Operating humidity 10 to 85 no condensation Storage temperature 20 to 50 C 4 to 122 F Accessories supplied Holder 1 Operation Manual 1 Design and specifications are subject to change without notice Holder Probe hea...

Страница 4: ...BKM 14L WW 3 859 002 05 1 Printed in Japan 2008 05 08 1996 9223 1893 11 Sony Corporation ...

Отзывы: