6-11
DNW-7/90/90WS
6-14. Crispening Adjustment (4:3)
6-15. Level Depandent Adjustment (4:3)
6-14. Crispening Adjustment (4:3)
4:3 mode
Preparation
.
On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: DETAIL
→
ON
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot a gray-scale chart (4:3) in the full underscan’s
picture frame.
Setting point
:
1
Lens IRIS
Spec.
: A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
Adjustment procedure
Equipment
: Black and white monitor
Test point
: TEST OUT connector
1.
On the setting menu, adjust as follows.
PAGE
: LEVEL 1
ITEM
: CRISPENING
Spec.
: Reduce the noise on the screen to a
permissible level.
A
A
B
6-15. Level Depandent Adjustment (4:3)
4:3 mode
Preparation
.
On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: DETAIL
→
ON
ITEM
: TEST OUT
→
ENC
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot a gray-scale chart (4:3) in the full underscan’s
picture frame.
Setting point
:
1
Lens IRIS
Spec.
: A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
Adjustment procedure
Test point: TEST OUT connector
1.
On the setting menu, adjust as follows.
PAGE
: LEVEL 1
ITEM
: LEVEL DEPEND
Spec.
: Eliminate the detail signal from portion
B.
Note
.
After this adjustment, be sure to perform 6-16. H/V
Ratio Adjustment, and 6-17. Detail Level Adjustment, in
that order.