background image

1-1(E)

AMS-100

1-1. Power Supply

1-1-1. Power Specifications

Power voltage

AC 100 to 240 V 

±

10 %

Current consumption

25 W

Inrush current

20 A

1-1-2. Power Cord

w

Use the specified power cord only when connecting.

Never use a injured power cord.

n

Ground the unit safely.

If the unit is used in the area except above, please consult

with local Sony’s sales/service office.

1. Installation

1-1.

Power Supply ........................................................................................ 1-1 (E)

1-1-1.

Power Specifications ............................................................ 1-1 (E)

1-1-2.

Power Cord ........................................................................... 1-1 (E)

1-2.

Dimensions ............................................................................................ 1-2 (E)

1-3.

Installation of Boards ............................................................................ 1-2 (E)

1-4.

Rack Mounting ...................................................................................... 1-3 (E)

1-5.

Pin Assignment of Connectors .............................................................. 1-4 (E)

1-6.

Matching Connectors and Cables .......................................................... 1-5 (E)

1-7.

Internal Switches ................................................................................... 1-5 (E)

1-7-1.

AL-42 Board (BKAM-101) ................................................. 1-5 (E)

1-7-2.

SDI-43 Board (BKAM-103) ................................................ 1-5 (E)

1-8.

 Input Level Meter Adjustment ............................................................. 1-6 (E)

1-9.

Related manuals .................................................................................... 1-6 (E)

Table of Contents

Section 1

Installation

Power code for the customer in the U.S.A.and Canada.

1

Power cord (approx. 2.4 m)

!

1-557-377-11

2

Plug holder (Black)

2-990-242-01

Power code for the customer in the United Kingdom.

1

Power cord set (approx. 2.4 m)

!

DK-2401 (UK)

2

Plug holder (Black)

2-990-242-01

Plug holder is supplied with DK-2401 (UK).

2

AC inlet

1

Power code for the customer in Europe except the United
Kingdom.

1

Power cord set (approx. 2.4 m)

!

DK-2401 (AE)

2

Plug holder (Black)

2-990-242-01

Plug holder is supplied with DK-2401 (AE).

AC inlet

2

1

AC inlet

2

1

Содержание AMS-100

Страница 1: ...AUDIO MONITOR SPEAKER SYSTEM AMS 100 ANALOG MODULE BKAM 101 AES EBU MODULE BKAM 102 SDI MODULE BKAM 103 INSTALLATION MANUAL 1st Edition ...

Страница 2: ... à moins d être qualifié pour en effectuer d autres Pour toute réparation faire appel à une personne compétente uniquement AMS 100 SY Serial No 10001 and Higher BKAM 101 SY Serial No 10001 and Higher BKAM 102 SY Serial No 10001 and Higher BKAM 103 SY Serial No 10001 and Higher Attention when the product is installed in Rack 1 Prevention against overloading of branch circuit When this product is in...

Страница 3: ...ectors 1 4 E 1 6 Matching Connectors and Cables 1 5 E 1 7 Internal Switches 1 5 E 1 7 1 AL 42 Board BKAM 101 1 5 E 1 7 2 SDI 43 Board BKAM 103 1 5 E 1 8 Input Level Meter Adjustment 1 6 E 1 9 Related manuals 1 6 E Table of Contents Section 1 Installation Power code for the customer in the U S A and Canada 1 Power cord approx 2 4 m 1 557 377 11 2 Plug holder Black 2 990 242 01 Power code for the cu...

Страница 4: ...ff the power of the AMS 100 2 Remove the blank panel on the rear panel after removing its two retainer screws n Do not discard the removed blank panel 3 Slide the optional board along the guide rails into the unit 4 Secure the optional board in the AMS 100 with the screws supplied with the optional board n If there is any unused slot without a cover install the cover you have just removed there B ...

Страница 5: ...2 pcs Screw B5x8 4 pcs Screw PWH4x10 2 pcs Plate nut 2 pcs Screw for inner rail B4x8 6 pcs Screw for rack mounting RK5x16 4 pcs Washer for rack mounting 4 pcs Sony part number 2 297 913 00 c Be sure to use the RMM 30 rack mount rail If a rack mount rail other than the RMM 30 is used the AMS 100 may be dropped by insufficient strength of the rack mount rail This may cause a injury Procedures 1 Turn...

Страница 6: ...gnment of Connectors REMOTE D sub 25 pin Female _External View_ Pin No Signal 1 REM A IN 2 REM B IN 3 REM CH SELECT L1 IN 4 REM CH SELECT L2 IN 5 REM CH SELECT R1 IN 6 REM CH SELECT R2 IN 7 GND 8 MONITOR OUT 2 H 9 MONITOR OUT 2 C 10 MONITOR OUT 1 H 11 MONITOR OUT 1 C 12 REM GROUP SEL 1 IN 13 REM GROUP SEL 2 IN 14 STS A OUT 15 STS B OUT 16 STS CH SELECT L1 OUT 17 STS CH SELECT L2 OUT 18 STS CH SELE...

Страница 7: ...al Switches 1 7 1 AL 42 Board BKAM 101 S2 CH 1 input level select switch To select the input level of CH 1 Factory setting 4 dB S22 CH 2 input level select switch To select the input level of CH 2 Factory setting 4 dB 1 7 2 SDI 43 Board BKAM 103 S101 Free run adjustment select switch for the serial decoder Used during free run adjustment of the serial decoder OFF Normal operation ON For free run a...

Страница 8: ...point Adjustment screw L input level meter Adjustment screw R input level meter Specification The LEDs for 0 level start blinking Setting after adjustment To return from Adjustment mode press any button on the INPUT SELECT operation panel 1 9 Related manuals Besides this Installation Manual the following manuals are available for the AMS 100 Operation Manual Supplied with the AMS 100 This manual e...

Страница 9: ...erselben für irgendeinen anderen Zweck als die Bedienung oder Wartung der in dieser Anleitung beschriebenen Ausrüstung ohne ausdrückliche schriftliche Erlaubnis der Sony Corporation SAFETY CHECK OUT After correcting the original service problem perform the following safety checks before releasing the set to the customer Check the metal trim metallized knobs screws and all other exposed metal parts...

Страница 10: ...Printed in Japan Sony Corporation 1999 2 11 Broadcasting Professional Systems Company 1999 AMS 100 SY BKAM 101 SY BKAM 102 SY BKAM 103 SY J E 3 202 309 01 ...

Отзывы: