14
AM-NX1
5. The display changes a shown below each time the
[DISPLAY]
key is pressed.
However in the power mode (item number 700’s), only the
item is displayed.
6. Quit the manual mode, and press the
x
key to return to the
test mode (display check mode).
LCD display
LCD display
LCD display
LCD display
LCD display
LCD display
C 6 8 S 0 1
011
item number
address
adjusted value
• Address & Adjusted Value Display
0 F E J 0 1
011
item number
jitter value
adjusted value
• Jitter Value & Adjusted Value Display
0 6 3 B 0 1
011
item number
block error value
adjusted value
• Block Error Value & Adjusted Value Display
0 5 9 A 0 1
011
item number
ADIP error value
adjusted value
• ADIP Error Value & Adjusted Value Display
0 1 5 F 0 1
011
item number
focus drive value
adjusted value
• Focus Drive Value & Adjusted Value Display
L r e f P w 0 1
011
item number
item title
adjusted value
• Item Title Display
Overall Adjustment Mode
Mode to adjust the servo automatically in all items.
Normally, automatic adjustment is executed in this mode at the
repair.
For further information, refer to “SECTION 5 ELECTRICAL
ADJUSTMENTS” (see page 17).
Self-Diagnosis Result Display Mode
This set uses the self-diagnostic function system in which if an
error occurred during the recording or playing, the mechanism
control block and the power supply control block in the micro-
computer detect it and record its cause as history in the nonvola-
tile memory.
By checking this history in the test mode, you can analyze a fault
and determine its location.
Total recording time is recorded as a guideline of how long the
optical pick-up has been used, and by comparing it with the total
recording time at the time when an error occurred in the self-diag-
nosis result display mode, you can determine when the error oc-
curred.
Clear both self-diagnosis history data and total recording time, if
the optical pick-up was replaced.
• Self-Diagnosis Result Display Mode Setting Method
1. Set the test mode (see page 12).
2. In the display check mode, press the
[DISPLAY]
key activates
the self-diagnosis result display mode where the LCD display
as shown below.
3. Then, each time the
>
key is pressed, LCD display descends
by one as shown below. Also, the LCD display ascends by one
when the
.
key is pressed.
If the
[DISPLAY]
key is pressed with this display, the LCD switches
to the simple display mode.
4. Quit the self-diagnosis result display mode, and press
the
x
key to return to the test mode (display check mode).
LCD display
F 0 0 0 0 0
0XX
error display code
history code
Total recording time
when error occurred
0
XX
F 0 * * * *
0
XX
N * * * *
0
XX
N 1 * * * *
0
XX
N 2 * * * *
0
XX
R _ * * * *
XX
: Error code
* * * *
: Total recording time
Содержание AM-NX1