7.Drive Diagnostics
7-2
SONY AIT-3Ex drive SDX-800V series Ver.1.0
If an error is detected during power-up, the drive will return CHECK CONDITION status to the host on the first
command received. The host shall issue a REQUEST SENSE command to determine the cause of the CHECK
CONDITION status. The Sense data returned by the drive will have a Sense Key of 6 (Unit Attention) and the
ASC/ASCQ will be 29 80 (Drive failed power or test or diagnostic). The host can then issue a RECEIVE
DIAGNOSTIC RESULT command to the drive in order to identify the specific diagnostic test that failed and the
failure error code.
The drive should be checked by a qualified person to determine what action should be taken.
7.2.2.
SEND DIAGNOSTIC command - Self Test
The host computer can request that the drive perform a Self Test on itself to verify that it is functioning normally. The
Self Test bit in the SEND DIAGNOSTIC command is set to one, and the Parameter List Length is ZERO. This
initiates the Self Test Diagnostic which is similar to the Power-on self test except that non-destructive RAM testing is
substituted for the destructive RAM tests.
If an error is detected during this test, the drive will return CHECK CONDITION status to the host. The host shall
issue a REQUEST SENSE command to determine the cause of the CHECK CONDITION status. The Sense data
returned by the drive will have a Sense Key of 4 (Hardware Error) and the ASC/ASCQ will be 44 00 (Internal Target
Failure). The host can then issue a RECEIVE DIAGNOSTIC RESULT command to the drive in order to identify the
specific diagnostic test that failed and the failure error code.
The drive should be checked by a qualified person to determine what action should be taken.
7.2.3.
SEND DIAGNOSTIC command - Individual Test
The SEND DIAGNOSTIC command also provides the capability to run each of the diagnostic tests individually. In
order to identify the diagnostic test to be executed, the SEND DIAGNOSTIC command should be configured as
follows:
Self Test bit = 0
Device Off-line bit = 0
Unit Off-line bit = 1
Parameter List Length = 5 or 9 (see below)
The SDX-800V supports both the SCSI-1 and SCSI-2 implementations of the SEND DIAGNOSTIC command.
In the SCSI-1 mode, the Page Format (PF) bit is ZERO and the Parameter List Length is 5, the Parameter List in this
case is 5 bytes long and will be of the form:
Table 7-1: SEND DIAGNOSTIC Parameter - SCSI-1
Bit
Byte
7 6 5 4 3 2 1 0
0
Diagnostic Test number
1
Break Loop
Count
2
Parameter A
3
Parameter B
4
Parameter C
Содержание AIT-SDX800
Страница 4: ...This page intentionally left blank ...
Страница 14: ...1 Introduction SONY AIT 3Ex drive SDX 800V series Ver 1 0 1 4 This page intentionally left blank ...
Страница 32: ...3 Installation SONY AIT 3Ex drive SDX 800V series Ver 1 0 3 8 This page intentionally left blank ...
Страница 42: ...4 Operation 4 10 SONY AIT 3Ex drive SDX 800V series Ver 1 0 This page intentionally left blank ...
Страница 56: ...5 SCSI Interface SONY AIT 3Ex drive SDX 800V series Ver 1 0 5 14 This page intentionally left blank ...
Страница 174: ...7 Drive Diagnostics 7 8 SONY AIT 3Ex drive SDX 800V series Ver 1 0 This page intentionally left blank ...
Страница 182: ...11 Appendix D 11 2 SONY AIT 3Ex drive SDX 800V series Ver 1 0 This page intentionally left blank ...
Страница 198: ...13 Appendix F SONY AIT 3Ex drive SDX 800 series Ver 1 0 13 4 This page intentionally left blank ...
Страница 204: ...15 Appendix H SONY AIT 3Ex drive SDX 800V series Ver 1 0 15 4 This page intentionally left blank ...