![Sony AIT-SDX560 Скачать руководство пользователя страница 84](http://html.mh-extra.com/html/sony/ait-sdx560/ait-sdx560_product-specifications-manual_420931084.webp)
7. ATAPI Packet Command Specification
LOG SENSE
SONY AIT-2 Turbo drive SDX-560V series Ver.1.0
7-14
7.6.3. Supported
Pages
The following log pages are supported:
Table 7-14: LOG PAGE Supported Log Pages
Page Code
Description
Allocation Length
00h
Supported Log Pages
12h
02h
Write Error Counter Page
20h
03h
Read Error Counter Page
20h
07h
Last n Error Events Page
1A8h (max)
30h
Tape Log Page (Sony Unique)
5Ch
31h
Tape Capacity Log Page
24h/404h (404h—AIT mode)
33h
Drive Usage Log Page (Sony Unique)
8Eh
34h
Write Frame Error Counter Page
3Ch
35h
Read Frame Error Counter Page
4Ch
39h
Transfer Log Page
5Ch
3Ch
AIT Log Page
90h X Partition4
Summary List of Supported Pages
The summary list of supported log pages returns the list of page codes supported by the target. This page is only
valid for the Log Sense command and if sent to the host during a Log Select command will cause termination with
CHECK CONDITION status with sense key set to ILLEGAL REQUEST and additional sense code of INVALID
FIELD IN PARAMETER LIST.
Table 7-15: LOG PAGE Supported Pages (00h)
Bit
Byte
7 6 5 4 3 2 1 0
0
Reserved
Page Code (00h)
1
Reserved
2
(MSB)
3
Page Length (n-3)
(LSB)
4
n
Supported Page List
(00 02 03 07 2E 30 31 33 34 35 39 3C)
The supported page list should be padded with zeros such that the entire page size is a multiple of four bytes. The
page length includes the pad bytes.
7.6.4.
Write and Read Error Counter Pages Code 02h & 03h
The Error Counters Pages (Write and Read) are used to report statistical information about Write and Read soft
and hard errors and retries. Each parameter is a counter which is updated by the target every time the
corresponding event occurs. The format of the Error Counters Pages is given below:
Table 7-16: LOG PAGE Error Counters (02h, 03h)
Bit
Byte
7 6 5 4 3 2 1 0
0
Reserved
Page Code (02h or 03h)
1
Reserved
2
(MSB)
3
Page Length (n)
(LSB)
4
(MSB)
5
Parameter Code
(LSB)
6
0 (DU)
1 (DS)
0 (TSD)
0 (ETC)
00 (TMC)
Reserved
0 (LP)
7
Parameter Length (n-3)
8
n
Parameter Value
Error Counter Page (Read 03h)
Error Counter Page (Write 02h)
The following parameter codes are supported for each Error Counters Page:
Содержание AIT-SDX560
Страница 4: ...This page intentionally left blank ...
Страница 26: ...3 Installation SONY AIT 2 Turbo drive SDX 560V series Ver 1 0 3 6 This page intentionally left blank ...
Страница 36: ...4 Operation SONY AIT 2 Turbo drive SDX 560V series Ver 1 0 4 10 This page intentionally left blank ...
Страница 152: ...8 Drive Diagnostics SONY AIT 2 Turbo drive SDX 560V series Ver 1 0 8 10 This page intentionally left blank ...