Working Instruction
,
Mechanical
1206-4797 Rev1
43(64)
3.28 Sub PWB Asm
REMOVAL
Follow the 2.1.1 – 2.1.6 Disassembly instructions!
Use Torx bit no 6 to remove the two screws.
Use a tweezer to disconnect the Sub PWB Asm
INSTALLATION
Use tweezers to position the Sub PWB Asm
Install two screws with torque screwdriver at 15
Ncm with a T6 bit.
Follow the 4.1.1 – 4.1.6 Reassembly instructions!
Company Internal
©
Sony Ericsson Mobile Communications AB