RS232 interface for GT47 embedded apps UART
2.2 3-Wire
RS232
In the 3-wire configuration, surface mount strap resistors (ST1 and ST2)
are not mounted. Flow control should be disabled on each communicating
device (AT+ IFC)
As the GT47 general purpose outputs each require a resistor pull-up,
these are provided on the RS232 interface PCB. The internal pull-up on
ST1 makes the CTS signal on the DB9 appear as ‘inactive’ state. As long
as flow control is disabled at the DTE this will not cause a problem. If flow
control cannot be disabled at the DTE, the ‘inactive’ state on CTS will
prevent the DTE from communicating. In this case, either solder a single
strap resistor between the pads of both ST1 and ST2 as shown in
or enable flow control from the GT47 and add straps ST1 and ST2 (see
section 2.3).
Figure 4
2.3 5-Wire
RS232
In the 5-wire configuration, surface mount strap resistors (ST1 and ST2)
must be mounted. This requires soldering 0603-size zero ohm resistors
into positions ST1 and ST2 as indicated in figure 3.
Adding the surface mount resistors should be performed by a skilled
technician and the PCB must first be disconnected from all communicating
devices.
2.4 DCE to DCE (Null-Modem)
If the GT47 UART is to be used as a DTE, instead of the default DCE
configuration, the following changes will be necessary. A 9-way DB9
gender-changer should be used to convert the output from a socket to a
plug. The following DB9 pin connections should be swapped
•
Pin-2 swapped with pin-3
•
Pin-7 swapped with pin-8.
The pin-swapping can be achieved by using a “Null-Modem” cable
between the DB9 plugs of the communication devices.
LZT 123 7698 R1B
7
Содержание RS232 interface for GT47 embedded apps UART
Страница 1: ...Application Note RS232 interface for GT47 embedded apps UART ...
Страница 10: ...RS232 interface for GT47 embedded apps UART APPENDIX A Figure 1 RS232 Converter Schematic LZT 123 7698 R1B 10 ...
Страница 11: ...RS232 interface for GT47 embedded apps UART APPENDIX B Figure 2 PCB Top Side LZT 123 7698 R1B 11 ...
Страница 12: ...RS232 interface for GT47 embedded apps UART Figure 3 PCB Bottom Side LZT 123 7698 R1B 12 ...
Страница 13: ...RS232 interface for GT47 embedded apps UART Figure 4 RTS CTS Flow Control Loop back LZT 123 7698 R1B 13 ...