SYSTEM CONNECTOR INTERFACE
44
LZT 123 8020 R1A
The LED states shown below, are hard coded
LED indication
Operational status
No indication
No power or in the OFF state
Green, steady
Power on, not connected to a network
Green, blinking
Power on, connected to a network
The following circuit is recommended for connecting an LED.
LED
10k
330
10k
BC817
GR47/48
DGND
VCC
Figure 5.10 Electrical connections for the LED
5.14 General Purpose Digital I/O Ports
Pin I/O
port
signal
Default
signal
Description
21
IO1
IO1
Programmable Input/Output 1
22 IO2
IO2
Programmable Input/Output 2
ADC5
23
IO3
IO3
Programmable Input/Output 3
24 IO4
IO4
Programmable Input/Output 4
13
IO5
IO5
Programmable Input/Output 5
ADC4
33 IO6
LED Programmable Input/Output 6/LED
43
IO7
TD3
Programmable Input/Output 7/TD3
44 IO8
RD3 Programmable Input/Output 8/RD3
39
IO9
RTS
Programmable Input/Output 9/RTS
37
IN1
DTR
Programmable Input 1
Data Terminal Ready
32
OUT3
DSR
Programmable Output 3/DSR
36
OUT2
RI
Programmable Output 2/RI
Ring Indicator
All manuals and user guides at all-guides.com