background image

S

S

o

o n

n o

o m

m a

a

S

S

o

o n

n o

o m

m a

a

P L A

P L A

T I N U M

T I N U M

E D I T I O N

E D I T I O N

TM

27" Natural Gas Conversion Manual

FOR OUTDOOR USE ONLY

Part No.

Qty

Description

1

44213827

1

Hose 27" - 3/8" Flare Both Ends for Side Burner (NG)

2

40275101

1

Main Burner Valve & Manifold Assembly with Valves (NG) 

3

44110102

2

Connector 3/8" MNPT x 3/8" Flare

4

44133801

1

Tee Fitting - Galvanized 3/8" Flare

5

49900004

1

Sealant Pipe (4ml)

6

44183815

1

Nipple Pipe 3/8" NPT x 1.5"

7

47311010

1

Regulator 3/8" FNPT Threads (NG)

8

46210102

1

Side Burner Valve Assembly - 12K BTU (NG)

9

08338381

1

3/8" Street Elbow

8

7

6

5

4

3

2

1

CANADIAN GAS ASSOCIATION

APPROVED

®

9

 

 

 

 

 

 

 

 

Содержание SGR27

Страница 1: ...h Ends for Side Burner NG 2 40275101 1 Main Burner Valve Manifold Assembly with Valves NG 3 44110102 2 Connector 3 8 MNPT x 3 8 Flare 4 44133801 1 Tee Fitting Galvanized 3 8 Flare 5 49900004 1 Sealant Pipe 4ml 6 44183815 1 Nipple Pipe 3 8 NPT x 1 5 7 47311010 1 Regulator 3 8 FNPT Threads NG 8 46210102 1 Side Burner Valve Assembly 12K BTU NG 9 08338381 1 3 8 Street Elbow 8 7 6 5 4 3 2 1 CANADIAN GA...

Страница 2: ... the bottom of the heat shield holding the front heat shield in place The screws are located under the bottom lip of the shield See Fig 5 6 Loosen the two 2 side heat shield screws located under the bottom lip of the heat shield There is one screw on each side See Fig 6 2 Tools Needed Phillips head screwdriver 1 4 nut driver Adjustable wrench Fig 4 Fig 1 Fig 2 Fig 3 SGR27 Natural Gas Conversion In...

Страница 3: ...ezel in place on the control panel See Fig 10 12 Remove the bezels from the front control panel Note The small bezel stays in place See Fig 11 13 Disconnect the right side flex line from the manifold using the adjustable wrench This will free up the right side of the manifold See Fig 12 14 Remove manifold from grill body See Fig 13 3 Fig 8 Fig 7 SGR27 Natural Gas Conversion Instructions Tabs Heat ...

Страница 4: ...grill body Line up the burners with the valves on the manifold making sure they are level See Fig 15 16 20 Reattach the igniters and their heat shields removed in Step Four 4 to the burners See Fig 3 on page 2 21 Reattach the rear heat shield before attaching the front heat shield to be sure the burners remain over the valves See Fig 17 22 At this point of the conversion a leak test should be perf...

Страница 5: ...For the following steps the supplied pipe dope needs to be applied to all indicated fittings before the fittings are screwed in Pipe dope should not be used on any flared fittings 3 Remove the grommet in the side of the cart by pressing in on the side with your fingers See Fig 20 4 Attach the T fitting to the main gas pipe as shown Tighten with wrench See Fig 21 5 Fig 18 Fig 19 Fig 20 SGR27 Natura...

Страница 6: ...arrow on the NG regulator indicating direction of gas flow The arrow should point toward the grill Remember to apply pipe dope 9 Attach one end of the supplied hose to the flared fitting on the side of the T connector See Fig 26 The other end of the hose will be attached to the side burner later 10 Replace the grommet in the side of the cart by pressing with your fingers See Fig 27 This completes ...

Страница 7: ...ob from the front of the side burner It should pull off by hand See Fig 30 4 Remove the two 2 screws holding the bezel and valve in place Remove bezel from the front of the side burner See Fig 31 5 Remove the two 2 screws holding the side burner LP valve assembly in place This will free up the assembly See Fig 32 7 Fig 29 Fig 32 Fig 31 Underside of side burner shelf Fig 28 SGR27 Natural Gas Conver...

Страница 8: ...ill be facing the igniter 8 Reattach the control knob 9 Carefully run the supplied hose from the inside of the cart through the grommeted hole in the cart to the side burner assembly 10 Connect the end of the new gas supply hose to the NG valve assembly See Fig 35 This completes the side burner conversion Note At the completion of the conversion a leak test should be performed on all fittings See ...

Отзывы: