3.2 Effect Section
3 DESCRIPTION OF CONTROLS
INPUT meter
the input meter displays the input drive levels. With the
CLIP 0dB
button (in the
Effect section) de-selected, the meter displays the level of overdrive applied to
the Inflator process. The meter will be mono or stereo depending on the
material content.
3.2 Effect Section
EFFECT fader
sets the amount of the overall Inflator effect that is applied to the programme,
from 0% to 100%.
EFFECT value
shows the value in dB of the parameter set by the
EFFECT
fader. The value
can be modified by clicking in the window.
EFFECT meter
indicates the degree of average signal modification in real time, depending on
programme type and Inflator settings.
CURVE fader
modifies the processing characteristics and sonic effect of the Inflator.
CURVE value
shows the value in dB of the parameter set by the
CURVE
fader. The value can
be edited by clicking in the window.
CLIP 0dB
when this button is selected, internal processing levels are restricted to the
equivalent of normal digital maximum. When de-selected, internal processing
may develop and process signals beyond the equivalent of digital maximum.
BAND SPLIT
selects processing on the direct full band signal or invokes a band splitting
function that processes the signal separately in the LF, MF and HF spectral
regions.
IN
This switches the Inflator process in and out for comparison purposes.
www.sonnox.com
13
Go to contents
Содержание Oxford