Sonnet Fusion R400S Скачать руководство пользователя страница 6

OS X Users’ Instructions

 

1.

 After changing the disk mode and turning on or restarting 

your computer, a Disk Insertion window will appear stating 
that there is an unreadable volume; click Initialize, and then 
Disk Utility will open.

 

2.

 In the Disk Utility window, the RAID group will appear as a 

single volume (or four volumes if the drive mode was set to 
JBOD). Select the volume, and then click the Erase tab at the 
top of the window. 

 3.

 Type in a name for the volume, and then click Erase; a 

window will appear asking you to approve your choice.

 4.

 Click Erase; the Fusion R400S RAID volume will appear on 

your computer’s desktop.

  5. If the drives were configured in any mode other than JBOD, 

skip to the next step. If the drives were configured in JBOD 
mode, repeat steps 2 – 4 for the remaining three drives.

 

5.

 Close Disk Utility; the Fusion R400S RAID is ready for use.

Windows 8/7/Vista/Server 2008 Users’ Instructions

 

1.

 Click Start, then right-click Computer, and then click Manage.

 2.

 In the Computer Management window, click Storage in the 

left pane to expand the list (if necessary), and then click Disk 
Management.

 

3.

 If you are using Windows Vista, an Initialize Disk window will 

appear; skip to step 4. If you are using Windows 8, 7, or Server 
2008, when the disks are displayed, the R400S RAID’s drives 
will appear as a single volume when configured in any mode 
other than JBOD (or as four drives if configured as JBOD), 
and listed as “unallocated”. Right-click where the words “Not 
Initialized” appear and select Initialize Disk.

 

4.

 In the Initialize Disk window, select GPT, and then Click OK.

 

5.

 Back in the Computer Management window, right-click where 

the word “Unallocated” appears, and then select New Simple 
Volume.

 6.

 When the New Simple Volume Wizard window appears, click 

Next.

 7.

 When the Specify Volume Size window appears, click Next if 

you want all of the R400S RAID’s capacity to remain as one 
block (volume). Otherwise, adjust the volume size to meet 
your needs, and then click Next. 

 8.

 When the Assign Drive Letter or Path window appears, select 

Assign the following drive letter, choose a letter, and then 
click Next.

OS Formatting Instructions

 

9.

 When the Format Partition window appears, enter a new 

name for the volume, select “Perform a quick format”, and 
then click Next.

Note:

  If you do not select the quick format option, this process will take 

much longer to complete.

 10.

 If the drives were configured in any mode other than JBOD, 

when the next window appears, click Finish; once “Healthy 
(Primary Partition)” appears, the R400S RAID is ready for use. 
If the drives were configured in JBOD mode, repeat steps 4 – 
10 with the remaining three drives.

Windows XP/Server 2003 Users’ Instructions

 1.

 Select Computer Management From the Windows Start menu. 

If it is not available in the Start Menu, select Start > Settings > 
Control Panel > Administrative Tools. In the Administrative 
Tools
 window, double-click Computer Management.

 2.

 In the Computer Management window, click Storage on the 

left, and then double-click Disk Management.

 

3.

 When the Initialize and Convert window appears, click OK.

 4.

 When the Select Disks to Initialize window appears, select the 

RAID volume or individual drive, and then click Next.

 5.

 When the next window appears, click Finish.

 

6.

 In the Disk Management window, the Fusion R400S RAID’s 

RAID group will appear (listed as “unallocated”) as a single 
volume, or as four volumes if the drives were configured 
in JBOD mode. Right-click where the word “unallocated” 
appears, and then select New Partition.

 7.

 When the Welcome to the New Partition Wizard window 

appears, click Next.

 8.

 When the Select Partition Type window appears, select Primary 

Partition, and then click Next. 

 

9.

 When the Specify Partition Size window appears, click next.

 

10.

 When the Assign Drive Letter or Path window appears, select 

Assign the following drive letter, choose a letter, and then 
click Next.

 

 Support Note for Windows XP Users:

 

Windows XP 

32-bit does not support volumes greater than 2TB

Windows XP x64, Windows Vista Ultimate/Enterprise (32- bit 
and 64-bit editions), and Windows Server 2003 support volumes 
greater than 2TB, but must be formatted using the GPT file system, 
which is not accessible by Windows XP 32-bit systems.

4

Содержание Fusion R400S

Страница 1: ...1U Rackmount 4 Drive Hardware RAID 5 SATA Storage System with eSATA Interface FUSION R400S RAID User s Guide For Windows ...

Страница 2: ......

Страница 3: ...tch for three or more seconds to activate the selected drive mode 4 Presence Activity and Fault Indicator LEDs for Drives 2 4 These LEDs indicate the ready state solid green read and write activity flashes green and fault status OFF for drives 2 4 Note that an LED will remain off if the corresponding drive is not recognized 5 Drive Modules To remove a drive module press its handle in until it pops...

Страница 4: ...e surface which it will reside Connect Fusion R400S RAID to Computer and Power Outlet 1 Using the supplied locking eSATA cable connect the Fusion R400S RAID to your computer 2 Connect the supplied power cable between the Fusion R400S RAID and a grounded wall outlet or power strip verify the cable is plugged in securely Drive Installation and Enclosure Setup 2 drive module Push in Support Note It i...

Страница 5: ...drag the icon to the eject icon in the dock 3 Using a small screwdriver turn the MODE Setting switch on the back of the enclosure to the position that matches the mode you wish to use Figure 3 4 Press and hold the MODE Change switch for more than three seconds Figure 3 the Drive 1 LED will light red while the LEDs for Drives 2 4 will light green until you release the button Figure 4 Once you relea...

Страница 6: ...Drive Letter or Path window appears select Assign the following drive letter choose a letter and then click Next OS Formatting Instructions 9 When the Format Partition window appears enter a new name for the volume select Perform a quick format and then click Next Note If you do not select the quick format option this process will take much longer to complete 10 If the drives were configured in an...

Страница 7: ...t option this process will take much longer to complete 13 If the drives were configured in any mode other than JBOD once the RAID group has been formatted and finishes building it is ready to use If the drives were configured in JBOD mode repeat steps 4 12 with the remaining three drives Linux Users s Information For Linux drive formatting information please contact your Linux Unix vendor Drive M...

Страница 8: ...re or the drive itself has failed There is a small chance that the enclosure is defective Clone RAID 5 or RAID 10 Rebuild After inserting a drive into the R400S RAID enclosure to replace a failed drive from a RAID 5 or RAID 10 group or putting in a new drive to be cloned to the Rebuild LED lights up orange and the Drive LEDs flash with activity until the RAID has been rebuilt or the clone copy com...

Страница 9: ...ations requiring higher performance and redundancy combining the attributes of RAID Levels 1 and 0 See Figure 10 RAID 10 offer 50 of the total capacity of the four drives Span Concatenation Volume Spans Four Drives Span mode creates a single large volume that spans all four drives writing files to the capacity of the first drive then the second drive and so on See Figure 11 Span mode provides no d...

Страница 10: ...rmation If you format the drives as JBOD and use the R400S RAID with an eSATA controller with no port multiplier support only one of the four drives will be accessible JBOD provides no data protection JBOD offers the full capacity of each of the drives Clone Data Mirrored on All Four Drives Clone mode enables all four drives to store the same files You may remove one of the four drives and replace...

Страница 11: ...40 MB s depending on interface used and drive configuration OS Support Platform independent Supported Drive Configurations Hardware based RAID 0 5 and 10 span clone and JBOD 1 Power Supply Universal 220W 100 240V AC 50 60Hz Operating Temperature 32 to 104 F 0 C to 40 C Dimensions WxDxH 17 0 x 16 25 x 1 75 in 43 2 x 41 3 x 4 4 cm Weight with drives approximate 20 2 lbs 9 16 kg RoHS Compliant Yes Pa...

Страница 12: ...Here and Fusion are trademarks of Sonnet Technologies Inc Mac the Mac logo Mac OS and OS X are trademarks of Apple Inc registered in the United States and other countries Other product names are trademarks of their respective owners Product specifications subject to change without notice Printed in the USA UG FUS R4SR5 WD E A 121212 ...

Отзывы: